带钢管剪力键的装配式混凝土桥墩抗震性能
引用本文:欧智菁,谢铭勤,秦志清,林上顺,俞杰.带钢管剪力键的装配式混凝土桥墩抗震性能[J].西南交通大学学报,2021,56(6):1169-1175, 1191.
作者姓名:欧智菁  谢铭勤  秦志清  林上顺  俞杰
基金项目:国家自然科学基金(51878172)
摘    要:为研究不同连接方式装配式混凝土桥墩的抗震性能,进行了2根装配式混凝土桥墩(连接构造分别为钢管剪力键和灌浆套筒)和1根现浇整体式混凝土桥墩的拟静力试验,分析对比试件的滞回曲线、骨架曲线、延性、刚度退化和耗能能力,采用ABAQUS通用程序建立有限元模型,并开展了有限元参数分析. 研究结果表明:3类桥墩试件水平荷载-位移滞回曲线较饱满,具有良好的抗震性能,均为整体压弯破坏,无明显的强度退化,累积耗能能力相近;在不同轴压比、长细比、混凝土强度和钢筋强度条件下,带钢管剪力键的装配式混凝土桥墩的水平峰值荷载和位移延性系数均优于传统灌浆套筒连接的装配式桥墩,提高幅值分别为4%~32%和8%~36%;轴压比、长细比、钢管剪力键嵌入深度和钢管直径是影响钢管剪力键连接的装配式混凝土桥墩抗震性能的重要参数. 

关 键 词:装配式桥墩    钢管剪力键    拟静力试验    抗震性能    骨架曲线
收稿时间:2020-02-04

Seismic Performance Test and FEM Analysis of Assembled Concrete Pier with Sleeve and Steel Tube Shear Connector
OU Zhijing,XIE Mingqin,QIN Zhiqing,LIN Shangshun,YU Jie.Seismic Performance Test and FEM Analysis of Assembled Concrete Pier with Sleeve and Steel Tube Shear Connector[J].Journal of Southwest Jiaotong University,2021,56(6):1169-1175, 1191.
Authors:OU Zhijing  XIE Mingqin  QIN Zhiqing  LIN Shangshun  YU Jie
Abstract:In order to study the seismic performance of assembled concrete piers in different connection modes, the quasi-static test of two assembled concrete piers (using steel tube shear connector and grouting sleeve connection, respectively) and a cast-in-place integral concrete pier was conducted, the hysteresis curve, skeleton curve, ductility, stiffness degradation and energy consumption capacity of the comparison test specimens were analyzed, the finite element model was established by ABAQUS general procedure ,and the finite element parameters were analyzed. The results show that the hysteretic loops of the three types of piers are full and have good seismic performance, the failure mode of specimens is integral bending failure, there is no obvious strength degradation, and the piers have similar energy dissipation capabilities. Under the conditions of different axial compression ratio, slenderness ratio, concrete strength and steel strength, the horizontal peak load and displacement ductility coefficients of assembled concrete piers with steel tube shear connector are better than that connected with traditional grouting sleeves, and the increase amplitude is 4%?32% and 8%?36%, respectively. Axial compression ratio, slenderness ratio, embedding depth of steel tube shear connector and steel tube diameter are important parameters that affect the seismic performance of assembled concrete piers connected by steel tube shear connector. 
Keywords:
点击此处可从《西南交通大学学报》浏览原始摘要信息
点击此处可从《西南交通大学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23