1.
码头钢结构防腐质量的好坏 ,直接影响码头钢结构完好性质量及使用年限。介绍了一种高效牺牲阳极阴极保护技术在码头钢管桩防腐中的应用 相似文献
2.
港口工程结构采用阴极保护措施来防止钢管桩的电化学腐蚀,其中以牺牲阳极应用最为广泛。牺牲阳极的设计参数选取、阳极块选择、施工安装对于钢结构的防护起到决定性的作用,文中结合金塘大浦口集装箱码头1#泊位钢管桩防腐对牺牲阳极的设计和施工要点进行系统阐述。 相似文献
3.
4.
牺牲阳极的阴极保护施工技术在海港码头工程中的应用 总被引:2,自引:0,他引:2
深水码头的基桩,普遍采用大直径钢管桩。由于长年处于海水状态下,作为主要海洋工程结构物钢管桩,其防腐工作极其重要。钢管桩牺牲阳极阴极保护是一种控制金属电化学腐蚀的保护方法。结合绿华山海上散货减载平台工程,介绍了牺牲阳极阴极保护技术的原理,介绍了阳极块水下焊接主要施工工艺,可供参考。 相似文献
5.
6.
7.
8.
9.
10.
11.
论述了在爆炸性气体环境中使用外加电流阴极保护系统时,设计、施工和使用过程中需要考虑的安全问题,对油品码头和液体化工码头钢结构的防腐提供了很好的参考价值。同时也提出了目前保护系统存在的主要问题。 相似文献
12.
Corrosion of steel structures in the marine environment is a major problem. The deterioration of this kind of structures is costly and difficult to predict both when designing new structures and when estimating the remaining service life time for existing structures. The aim of this investigation was to find indicative values for the corrosion rate of steel sheet piles on the Swedish west coast. Such corrosion rates (mm/year) can be used both when designing new structures by oversizing the steel thickness and when estimating the bearing capacity of existing sheet pile structures. Earlier investigations on the corrosion rates along the Swedish east coast – with salinity from about 0.2% to 0.8% – are still used today as guidelines for the corrosion rate of all steel structures in the Swedish maritime environment even though the salinity on the west coast can be as high as 3.0%.Steel sheet pile wharfs located in the port of Halmstad on the Swedish west coast were inspected by ultrasonic measurements. Three wharf structures with a total length of about 700 m were inspected. None of the inspected wharfs had or have had cathodic protection. The thickness measurements of the steel sheet pile structures were performed by divers.The age of the three inspected sheet pile structures ranged from 36 to 51 years. The dimensions of the original sheet pile sections are known. One of the quay structures is located along a river. The salinity at all wharfs varied from low values at the surface to approx. 2% at the bottom (also in the river outflow).The measured average corrosion rates were in the same order as the design values in the European code. However, the results indicate increased corrosion rates about 1 m below the mean water surface and at the level of the propellers from the ships berthing the most frequented of the inspected wharfs, 3–6 m below water surface.The tolerances of steel sheet thicknesses – usually in the order of ±6% – are often neglected when investigating the remaining thickness in steel sheet piles. A simple calculation model shows that the sheet pile must be almost 50 years of age before an accurate estimation on the corrosion rate can be made, considering the tolerances, if the true original sheet pile thickness is not known. 相似文献
13.
确定和提高高桩码头钢管桩的承载力是工程界一直致力于研究的问题。结合多年来的高桩码头钢管桩基的施工工程实例,分析了钢管桩的受力机理,介绍了在同等条件下提高钢管桩承载力的方法。 相似文献
14.
介绍锦州港第三港池301B油品泊位钢管桩牺牲阳极阴极保护设计及实施情况。通过全面检查测量,所有钢管桩保护电位均在-1 043~-915 mV之间(相对银/氯化银/海水参比电极)。表明该工程钢管桩防腐设计是合理的,钢管桩得到了充分的保护。 相似文献
15.
16.
17.
18.
通过具体工程实例从桩基施工、单桩承载力、单桩完整性、打桩应力诸方面介绍了PHC桩(预应力高强混凝土管桩)在天津港码头工程中的应用,着重从单桩承载力方面进行介绍,并对经济成本方面与钢管桩进行了对比,并提出了PHC桩在天津港地区应用还需解决的某些问题。 相似文献