首页 | 本学科首页   官方微博 | 高级检索  
     检索      

HX_D1B型机车高压电缆接地方式改进
引用本文:彭艳华,颜罡.HX_D1B型机车高压电缆接地方式改进[J].电力机车与城轨车辆,2009,32(6):31-32,43.
作者姓名:彭艳华  颜罡
作者单位:南车株洲电力机车有限公司,湖南,株洲,412001
摘    要:HXD1B型机车在型式试验过程中,由于高压电缆屏蔽层的影响,导致TCU检测到原边电流和回流电流的差值超过50A,进而出现跳主断保护的故障现象,文章对其进行理论分析和试验验证,并提出改进措施。

关 键 词:HXD1B型机车  高压电缆接地方式  电流互感器  TCU保护  分析

Improvement of earthing mode for high voltage cable on type HX_D1B locomotive
PENG Yan-hua,YAN Gang.Improvement of earthing mode for high voltage cable on type HX_D1B locomotive[J].Electric Locomotives & Mass Transit Vehicles,2009,32(6):31-32,43.
Authors:PENG Yan-hua  YAN Gang
Institution:PENG Yan-hua,YAN Gang (CSR Zhuzhou Electric Locomotive Co.,Ltd.,Zhuzhou 412001,China)
Abstract:This paper presents a failure of main circuit breaker protection,for the difference between main and return current detected by TCU is more than 50 A,which caused by the earthing of the high voltage cable screen during the type test of type HXD1B locomotive. The paper analyses it for theoretics,validates it by test,and brings a newmodifying measure.
Keywords:HXD1B locomotive  earthing mode for high voltage cable  current transducer  TCU protection  analysis  