Effects of micro-arc oxidation coating on corrosion behavior of Mg-Y-Zn in simulated body fluid
Authors:Tian-feng Lu  Kai-yang Yin  Bing-yi Sun  Qing Dong  Bin Chen
Institution:1. School of Materials Science and Engineering, Shanghai Jiaotong University, Shanghai, 200240, China
Abstract:The application of magnesium and its alloy as degradable biomaterials is mainly confined due to its high degradation rate in physiological environment. This research focused on the effects of micro-arc oxidation (MAO) on biodegradable behavior of Mg-Y-Zn magnesium alloy in a simulated body fluid (SBF). The corrosion rate of alloys was gauged by means of hydrogen evolution volume measurement and mass-loss method. Scanning electron microscope (SEM) was utilized to observe the surface of the magnesium alloy and the cross-section of oxidation coating layer before and after corrosion. The Mg-Y-Zn alloy with thicker oxidation coating exhibited greater corrosion resistance during the immersion test for 240 h.
Keywords:corrosion behavior  biomedical magnesium alloys  micro-arc oxidation (MAO)
本文献已被 维普 SpringerLink 等数据库收录!