首页 | 本学科首页   官方微博 | 高级检索  
     检索      

电源配电车低温启动后停机的故障树分析
引用本文:倪峰,李锐敏,杨淑霞.电源配电车低温启动后停机的故障树分析[J].移动电源与车辆,2014(3):28-30.
作者姓名:倪峰  李锐敏  杨淑霞
作者单位:郑州金阳电气有限公司,郑州450006
摘    要:某型号电源配电车做环境试验,低温环境启动成功后停机。更换手打输油泵后,启动成功,工作正常。针对这种现象,根据低温启动的技术要求和原理、发电机组低温启动成功后停机故障树,分析原因,现场采取措施有效,实施效果良好,得到了同行的认可及推广。

关 键 词:低温启动  输油泵

Fault Tree Analysis of Power Distribution Vehicle Started Stop in Low Temperature
NI Feng,LI Rui-Min,YANG Shu-Xia.Fault Tree Analysis of Power Distribution Vehicle Started Stop in Low Temperature[J].Movable Power Station & Vehicle,2014(3):28-30.
Authors:NI Feng  LI Rui-Min  YANG Shu-Xia
Institution:( Zhengzhou Jinyang Electrical Co. , LTD. , Zhengzhou 450006, China)
Abstract:The type power distribution vehicle for environmental testing,low temperature environment stop after a successful started. After change hands oil transfer pump,start the success,working properly. In this paper,according to this phenomenon,the technology requirements of the low temperature start and principle,generating set after the success of the low- temperature start stop the fault tree,analysis the reason,the measures to effectively,implementing effect is very good and get the approvl.
Keywords:low temperature start  hand oil transfer pump