摘    要:本文总结25例内听道桥小脑角池造影检查资料,确诊为听神经瘤者6例,4例为道内小型肿瘤,2例属中型。8例同时作空气造影CT与之对比。初步体会:此法安全、客观、分辨率很高、诊断可靠,显示道内肿瘤和微细结构较空气造影CT法更为清晰,是早期听神经瘤诊断中十分准确和极为实用的一种检查法,并能为其他内听道疾病的临床诊断提供更多的信息。

关 键 词:内听道—桥小脑角池造影  空气造影CT  听神经瘤

CLINICAL APPLICATION OF MEATOCISTERNOGRAPHY——ANALYSIS OF 25 CASES
Zhang Quanan,et al.CLINICAL APPLICATION OF MEATOCISTERNOGRAPHY——ANALYSIS OF 25 CASES[J].Journal of Xi‘an Jiaotong University:Medical Sciences,1988(4).
Authors:Zhang Quanan  
Abstract:This paper reports 25 cases of meatoci-sternography, six cases of acoustic neuromas were diagnosed by it. Among them. 4 cases were of small type and 2 cases, medium Meatocisterncgraphy was compared with CT/ air cisterhography in 8 cases. Our prelimi nary experience shows that meatocisternography is a safe, objective method, with a high distiguishable rate; The diagnosis is trutworthy. The makes small acoustic neuromas and microstructure clearer than CT/ air cisternography in the internal auditory canal. This examination is a very accurate and useful method for detecting small acoustic neuromas and offers more information for other diseases in the internal auditory canal.