摘    要:对黄骅港某港区钢筋混凝土梁、板构件强度和电通量进行测试,比较梁、板构件混凝土强度和电通量的差异性。结果表明,混凝土强度差别不大时,电通量和强度没有对应关系;强度和电通量差别较大(超过5MPa)时,高强度对应低电通量。

关 键 词:强度  电通量  结构实体  氯离子  渗透性

Relationship between Chloride Permeability of Concrete Mass and Its Strength
YANG Hong-chao.Relationship between Chloride Permeability of Concrete Mass and Its Strength[J].China Harbour Engineering,2011(4):47-48.
Authors:YANG Hong-chao
Institution:YANG Hong-chao(Port &Waterway Engineering Quality & Safety Supervision Bureau of Hebei Province,Tianjin 300132,China)
Abstract:The strength and electric flux of reinforced concrete beams and slabs in a part area of Huanghua Port were tested and the differences of the strength and electric flux of reinforced concrete beams and slabs were compared.The results indicate that the electric flux has no correspondence with the strength when the differences of concrete strength are not significant;but when the difference between strength and electric flux is bigger(more than 5 MPa),high strength is corresponding to low electric flux.