牵引网异相短路时馈线保护装置动作分析
引用本文:董智慧,韩正庆,李攀宏.牵引网异相短路时馈线保护装置动作分析[J].电气化铁道,2013(6):12-15.
作者姓名:董智慧  韩正庆  李攀宏
作者单位:西南交通大学电气工程学院
摘    要:交流电气化铁路中,当电力机车不降弓带电通过电分相时可能发生异相短路故障。发生异相短路故障时,传统的馈线保护装置可能动作不正常,使得故障线路不能被及时切除,给铁路运营系统带来了不小的影响。通过Matlab/Simulink建立锚段关节式电分相异相短路模型,分析传统馈线距离保护装置和馈线电流保护装置拒动的原因。

关 键 词:异相短路  锚段关节式  馈线保护  拒动

Analysis of Actions of Feeder Wire Protection Device as Traction Network is being in Wrong-phase Short Circuit
DONG Zhi-hui;HAN Zheng-qing;LI Pan-hong.Analysis of Actions of Feeder Wire Protection Device as Traction Network is being in Wrong-phase Short Circuit[J].Electric Railway,2013(6):12-15.
Authors:DONG Zhi-hui;HAN Zheng-qing;LI Pan-hong
Institution:DONG Zhi-hui;HAN Zheng-qing;LI Pan-hong;
Abstract:Out-of-phase short-circuit fault may occurred when en-energized electric locomotives do not bow down through neutral section in AC electrified railway.Traditional feeder relays may mis-operate in this condition,it makes the fault line can not be resected promptly,and the fault brought huge impact to railway operation system.An out-of-phase short-circuit fault simulation model of overlap-structure neutral section was built in MATLAB/Simulink to analysis reasons why traditional feeder relays cannot protect against out-of-phase short-circuit fault.
Keywords:out-of-phase short-circuit  overlap-structure  feeder relay  mis-operate