摘    要:简要介绍了漏泄同轴电缆的原理和基本性能,提出了以提高接收电平作勾选择和配置漏泄同轴电缆基本要求的计算方法,并举出了实例,还提出了建议。

关 键 词:漏泄同轴电缆  基本要求  接收电平  末端接收电平等值  最长无中继覆盖距离

Selection,Configuration and Proposal about Leaky Coaxial Cable Used for Metro
Xv Hualin.Selection,Configuration and Proposal about Leaky Coaxial Cable Used for Metro[J].Railway Signalling & Communication Engineering,2005(1):35-39.
Authors:Xv Hualin
Abstract:The principle and basic pertormances ot leaky coaxial cable are briefly introduced,me calculation method of basic requirements is put forward to select and configure leaky coaxial cable to increase the receiving level,and the proposal is offered in the example given in the article.
Keywords:Leaky coaxial cable  Basic requirement  Receiving level  Terminal receiving level equivalence  and Maximum scope without repeater coverage  