Internal Force Distribution in Steel-Concrete Composite Structure for Pylon of Cable-Stayed Bridge
Authors:PU Qian-hui  BAI Guang-liang
Institution:School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China
Abstract:Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure the safety of the steel-concrete composite structure, a stud connector model for the joint section was put forward. Experiments were conducted to obtain the relation between load and slip of specimen, the failure pattern of stud connector, the yield bearing capacity and ultimate bearing capacity of a single stud, etc. The whole process of the structural behavior of the specimen was comprehensively analyzed. The features of the internal force distribution in the steel-concrete composite structure and the strain distribution of stud connector under different loads were emphatically studied. The test results show that the stud connector is applicable for the steel-concrete composite structure for pylon of Jintang bridge. The stud has a good ductility performance and a obvious yield process before its destruction. The stud connector basically works in a state of elasticity under a load less than the yield load.
Keywords:Stud connector  Experimental research  Steel-concrete composite structure  Cable-stayed bridge  Internal force distribution