摘    要:应用P-5L_2型数字粉尘计与配有符合BMRC粒度分级标准予捕集器的粉尘采样器,置于各粉尘作业场,同时、同步测定呼吸性粉尘与总粉尘质量浓度及相对质量浓度,通过相关分析与计算,求得粉尘质量浓度转换K与K_1值,及CPM与mg/m~3换算图。

关 键 词:浓度  质量浓度  粉尘  测定

Study on couvcrsion method for re1ative mass concentration into mass concentration in dust measurement
Tan Hong,Le Shangkan,Cui Zhenguo.Study on couvcrsion method for re1ative mass concentration into mass concentration in dust measurement[J].Railway Occupational Safety Health & Environmental Protection,1993(1):63-66.
Authors:Tan Hong  Le Shangkan  Cui Zhenguo
Institution:Tan Hong;Le Shangkan;Cui Zhenguo
Abstract:The study group in the Railway Ministry on conversion method of relative mass concentration intomass concentration(710054) This article reports that mass concentration and telative mass concentration of airborne respirabledust,and total dust were measured at same time and Place by using dust indicator furnish with separatorconform to BMRC size classified standard and P-5L_2digital dust indieator which were put in every dustworking Place.The convension coefficient K.and K_4 for transform relative mass concentration of airborntotal dust into mass concentration conversion graph of CPM and mg/m~3 were gotten by correlationanalysis and calculation