摘    要:对离心泵叶轮入口处液体的流动状态进行了分析,提出了采用固装式前置导翼改善叶轮叶片入口处液体的流动状态,以在降低流体噪声的同时,提高泵的效率,改善汽蚀性能.

关 键 词:流体机械及流体动力工程  离心泵  前置导翼  降噪
文章编号:1000-6982(2006)01-0046-04
收稿时间:2005-06-15
修稿时间:2005-08-15

Reducing hydraulic noise of fluid in the impeller inlet by means of adding front inducer
WU Ren-rong.Reducing hydraulic noise of fluid in the impeller inlet by means of adding front inducer[J].Ship Engineering,2006,28(1):46-49.
Authors:WU Ren-rong
Institution:Shanghai Marine Equipment Research Institute, Shanghai 200031, China
Abstract:The paper analyzes the flowing condition of the liquid in the impeller inlet of the centrifugal pump. Then it is suggested to adopt a fixed front inducer to improve the flowing condition of the liquid in the impeller inlet, in order to reduce hydraulic noise of fluid and at the same time to raise pump efficiency and improve its cavitation erosion property.
Keywords:fluid machinery and fluid dynamic engineering  centrifugal pump  front inducer  noise reduction