引用本文: | 蒋喜锋,王轶峰,陈晓东. SS_4改型机车管路防寒措施探讨[J]. 电力机车与城轨车辆, 2002, 25(Z1): 35-36 |
| |
作者姓名: | 蒋喜锋 王轶峰 陈晓东 |
| |
作者单位: | 哈尔滨南机务段,黑龙江,哈尔滨,150000 |
| |
摘 要: | 针对SS4改型机车在哈尔滨地区冬季的实际运行情况,详细阐述了SS4改型机车管路系统的防寒措施,重点说明了电加热防寒的方法以及防寒效果,对电力机车在寒带地区的防寒改造有一定的借鉴和参考价值。
|
关 键 词: | 电力机车 管路 防寒 措施 |
文章编号: | 1007-0656(2002)07-0035-02 |
修稿时间: | 2002-10-15 |
Cold-proof measures for pipeline system on type SS4 modified locomotive |
| |
Abstract: | According to the running actuality of type SS 4 modified electric locomotive in Harbin in winter,this paper puts forward cold-proof measures for its pipeline system,with the emphasis on measures and effect of electric heating.It offers reference for the cold-proof remodelling of electric locomotive running in frigid zone. |
| |
Keywords: | electric locomotive pipeline cold-proof measure |