首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Flow-injection-enhanced chemiluminescence method for the determination of three β-blockers
作者单位:[1]nstitute of Analytical Sciences, School of Sciences [2]Medical School, Xi'an Jiaotong University, Xi'an 710061, China.
摘    要:Objective To develop a rapid, simple and sensitive chemiluminescence method for the determination of three β-blockers (bisoprolol, atenolol and propranolol). Methods The chemiluminescence of cerium (Ⅳ)-sulfite system was obviously sensitized by adding anyone of three β-blockers in acid media. A new chemiluminescence method was set up by combining with flow-injection technique and used to determine the three β-blockers. Results Good linear ranges were obtained at the concentrations of 2.0×10-7g/mL-4.0×10-5g/mL, 1.0×10-7g/mL-3.0×10-5g/mL and 7.0×10-7g/mL-1.0×10-5g/mL, respectively, with the detection limits of 5.0×10-8g/mL, 7.0×10-8g/mL and 5.0×10-8g/mL (S/N=3), respectively, and the relative standard deviations for 11 times consecutive injections of 1.0×10-6g/mL bisoprolol, atenolol and propranolol were 3.57%, 2.21% and 2.26%, respectively. Conclusion The developed method is sensitive, accurate, rapid and of low cost. And it can be applied to determine bisoprolol, atenolol and propranolol in pharmaceutical preparations.

关 键 词:流动注射技术  化学发光法  阻断剂  测定  比索洛尔  阿替洛尔  普萘洛尔  酸性介质

Flow-injection-enhanced chemiluminescence method for the determination of three β-blockers
Authors:Li-Juan Wang  Yu-Hai Tang  Bao-Ping Li  Hong-Lang Liu  Jing-Feng Yi
Abstract:Objective To develop a rapid, simple and sensitive chemiluminescence method for the determination of three β-blockers (bisoprolol, atenolol and propranolol). Methods The chemiluminescence of cerium (Ⅳ)-sulfite system was obviously sensitized by adding anyone of three β-blockers in acid media. A new chemiluminescence method was set up by combining with flow-injection technique and used to determine the three β-blockers. Results Good linear ranges were obtained at the concentrations of 2.0×10-7g/mL-4.0×10-5g/mL, 1.0×10-7g/mL-3.0×10-5g/mL and 7.0×10-7g/mL-1.0×10-5g/mL, respectively, with the detection limits of 5.0×10-8g/mL, 7.0×10-8g/mL and 5.0×10-8g/mL (S/N=3), respectively, and the relative standard deviations for 11 times consecutive injections of 1.0×10-6g/mL bisoprolol, atenolol and propranolol were 3.57%, 2.21% and 2.26%, respectively. Conclusion The developed method is sensitive, accurate, rapid and of low cost. And it can be applied to determine bisoprolol, atenolol and propranolol in pharmaceutical preparations.
Keywords:flow-injection  chemiluminescence
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号