不同冷凝风量对冷藏集装箱运行特性影响的试验研究 |
| |
引用本文: | 薛威,郑超瑜,陈武.不同冷凝风量对冷藏集装箱运行特性影响的试验研究[J].船海工程,2012,41(5):98-101. |
| |
作者姓名: | 薛威 郑超瑜 陈武 |
| |
作者单位: | 集美大学轮机工程学院,福建厦门,361021 |
| |
基金项目: | 福建省科技重点项目,厦门市科技计划项目 |
| |
摘 要: | 采用试验的方法,在相同的外界环境温度和湿度条件下,模拟最常见的两种引起冷藏集装箱冷凝风机风量下降的因素。试验结果表明,风机性能下降及垛距过小会减少冷凝风机的冷凝风量,从而增加系统制冷时间和功耗;为了保证有效通风,垛距至少要达到1 m才能保证冷凝风机有效工作。
|
关 键 词: | 冷藏集装箱 变冷凝风量 垛距 |
Experimental Study on the Operational Characteristics of Refrigerated Containers Impacted by Different Condensing Air Flow Rate |
| |
Authors: | XUE Wei ZHENG Chao-yu CHEN Wu |
| |
Institution: | (College of Marine Engineering,Jimei University,Xiamen Fujian 361021,China) |
| |
Abstract: | In the same external environment temperature and humidity conditions,the experimental tests were deployed to monitor two common factors that reduce condensing air flow rate.The experimental results showed that reduced condensing fan performance and too small container distance will decrease condensing air flow rate,and increase the cooling time and power consumption.In order to ensure effective work of condensing fan,the container distance should not be less than 1 meter. |
| |
Keywords: | refrigerated container variable condensing air flow container distance |