作者单位:大秦铁路股份有限公司 湖东电力机务段 技术科,山西大同,037005
摘    要:针对HXD2机车辅助变流器隔离问题,从引起辅助变流器隔离的原因进行梳理分析,并提出相应的故障解决措施,为同类机车检修提供一定的参考。

关 键 词:辅逆隔离  恒频  变频  回路

Cause Analysis and Countermeasure of Auxiliary Converter Isolation Fault for HXD2 Electric Locomotive
XU Wenguo.Cause Analysis and Countermeasure of Auxiliary Converter Isolation Fault for HXD2 Electric Locomotive[J].Railway Locomotive & Car,2014,34(5):63-65.
Authors:XU Wenguo
Institution:XU Wenguo(R&D Center of Hudong Locomotive Depot, Daqin Railway Co. , Ltd. , Datong 037005 Shanxi,China)
Abstract:Aiming at the auxiliary converter isolation problem of HXD2 locomotive, this paper analyzes the cause of fault, and puts for ward the corresponding measures to resolve the failures, which can provide reference for similar locomotive maintenance.
Keywords:auxiliary converter isolation  constant frequency  variable frequency  circuit