配电所控制回路故障及改进技术
引用本文:李嘉,胡仲霞.配电所控制回路故障及改进技术[J].电气化铁道,2010,21(5):29-30.
作者姓名:李嘉  胡仲霞
作者单位:1. 四川大学计算机(软件)学院,四川,成都,610207
2. 四川大学电子信息学院
摘    要:配电所开关柜均采用电磁操作机构的真空断路器,在日常的操作、检修和试验中频繁烧毁合闸线圈,对设备的安全运行构成隐患。本文从发现运输生产一线的设备故障入手,通过调查分析并提出了改进技术,对高速铁路的电力系统控制回路技术有一定的借鉴意义。

关 键 词:配电所  控制回路  故障及改进技术

Power Supply Distribution Substation Control Circuit Fault and Technology for its Improvement
LI Jia,HU Zhong-xia.Power Supply Distribution Substation Control Circuit Fault and Technology for its Improvement[J].Electric Railway,2010,21(5):29-30.
Authors:LI Jia  HU Zhong-xia
Institution:LI Jia,HU Zhong-xia
Abstract:The switchgear in the substation use the vacuum circuit breaker of the electromagnetic operating mechanism.In the daliy operation,maintenance and experiment,the closing coils are burnout frequently,it endangered the equipment.The equipment faults collected from the production frontier are analyzed,some advices are proposed,and it is significant for improving the control circuit technology of the power system in the high-speed railway age.
Keywords:substation  control circuit  fault and improve technology  