摘    要:To utilize exist SCADA(Supervisory Control and Data Acquisition)/EMS (Energy Management System) fully and economize capital, Henan Electric Power Dispatching and Communication Center in China established a set of Henan Dispatcher Training Simulator (HNDTS) base on its exist SCADA/EMS. In order to integrated with exist SCADA/EMS, the integration method and technique are proposed. Graph data integration discussed with emphasis.After integration implemented, HNDTS can share all data with SCADA/EMS and dispatchers can be trained in same environment as real work situation, in the same time it can avoid amout of work of maintenance engineers. Both advantages and disadvantages of integration are analyzed. In the end of paper, the requirement for future DTS is put forward base on the experience of author.

关 键 词:SCADA  EMS  DTS

A DISPATCHER TRAINING SIMULATOR SYSTEM INTEGRATED WITH THE EXIST SCADA/EMS
Hua Bin,Zhou Jianzhong College of Hydroelectricity and Digitalization Engineering,Huazhong Uni versity of Science and Technology,Wuhan ,China..A DISPATCHER TRAINING SIMULATOR SYSTEM INTEGRATED WITH THE EXIST SCADA/EMS[J].Academic Journal of Xi’an Jiaotong University,2004,16(2):132-135,139.
Authors:Hua Bin  Zhou Jianzhong College of Hydroelectricity and Digitalization Engineering  Huazhong Uni versity of Science and Technology  Wuhan  China
Institution:College of Hydroelectricity and Digitalization Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
Abstract:To utilize exist SCADA(Supervisory Control and Data Acqui si tion)/EMS (Energy Management System) fully and economize capital, Henan Electric Power Dispatching and Communication Center in China established a set of Henan Dispatcher Training Simulator (HNDTS) base on its exist SCADA/EMS. In order to i ntegrated with exist SCADA/EMS, the integration method and technique are propose d. Graph data integration discussed with emphasis. After integration implemented , HNDTS can share all data with SCADA/EMS and dispatchers can be trained in same environment as real work situation, in the same time it can avoid amout of work of maintenance engineers. Both advantages and disadvantages of integration are analyzed. In the end of paper, the requirement for future DTS is put forward bas e on the experience of author.
Keywords:system integration  dispatcher training simulator  (DTS)  power system
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号