DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE BY FLOW-INJECTION CHEMILUMINESCENCE METHOD
作者姓名:唐玉海  韩小年  于春玲  孙媛媛  姚宏
作者单位:Department of Chemistry Sciences College of Xi'an Jiaotong University Xi'an 710061 China,Department of Chemistry Sciences College of Xi'an Jiaotong University Xi'an 710061 China,Department of Chemistry Sciences College of Xi'an Jiaotong University Xi'an 710061 China,Department of Chemistry Sciences College of Xi'an Jiaotong University Xi'an 710061 China,Department of Chemistry Sciences College of Xi'an Jiaotong University Xi'an 710061 China
摘    要:Tetracycline and oxytetracycline are broad-spec-trumantibiotics.They are not only used in humanpathologies,but alsoin veterinary medicine,ani malnutrition and feed additives for cattle breeding.In the past few years,the deter mination meth-ods of tetracycline and oxytetracycline were repor-ted,which involved in difference spectrophotome-try1],HPLC2,3],spectrophotometry4-7],HPLC-MS8-9],spectrofluori metry10],solid-phase extrac-tion11]and kinetic methods.Recently,flow-injection CL met…

关 键 词:流动注入  四环素  土霉素  药物分析
文章编号:1671-8267(2006)02-0136-03

DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE BY FLOW-INJECTION CHEMILUMINESCENCE METHOD
Tang Yuhai,Han Xiaonian,Yu Chunling,Sun Yuanyuan,Yao Hong.DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE BY FLOW-INJECTION CHEMILUMINESCENCE METHOD[J].Academic Journal of Xi’an Jiaotong University,2006,18(2):136-138.
Authors:Tang Yuhai  Han Xiaonian  Yu Chunling  Sun Yuanyuan  Yao Hong
Abstract:Objective To establish a rapid and precise continuous flow-injection chemiluminescence method for the determination of tetracycline and oxytetracycline. Methods In NaOH solution, tetracycline and oxytetracycline can sensitize obviously the chemiluminesence (CL) intensity of the reaction of luminol with KIO4, the sensitized CL intensity is proportional to the concentration of tetracycline and oxytetracycline. So, a new flow-injection CL method has been developed. The optimum chemical conditions for the CL reaction were investigated. Results Under the optimized conditions (KIO4 concentration: 1.0×10-5 mol/L; NaOH concentration: 0.1 mol/L; luminol concentration: 1.0×10-4mol/L), tetracycline and oxytetracycline were determined. The linear range of the working curves was 1.0×10-7 -1.0×10-4g/mL, the detection limits was 1.0×10-8g/mL and 1.1×10-8g/mL, and the relative standard deviation was 2.6% (CS=1.0×10-6g/mL; n=11) and 2.0% (CS=1.0×10-6g/mL; n=11) respectively. Conclusion The method is simple, rapid, and sensitive, and it has been successfully applied to the the determination of tetracycline and oxytetracycline tablets, the mean recoveries being 99.7% and 98.8% respectively.
Keywords:flow-injection  chemiluminescence  tetracycline  oxytetracycline