首页 | 本学科首页   官方微博 | 高级检索  
     检索      

现役桥梁混凝土钢筋在自然环境下的锈蚀特征及分级评价
引用本文:郝保红,;曾丁,;盛敏徽,;宋夕洋.现役桥梁混凝土钢筋在自然环境下的锈蚀特征及分级评价[J].武汉水运工程学院学报,2014(6):1329-1332.
作者姓名:郝保红  ;曾丁  ;盛敏徽  ;宋夕洋
作者单位:[1]北京石油化工学院机械工程学院,北京102617; [2]交通运输部公路科学研究院,北京100088
基金项目:重大科技专项基金资助(批准号:318223390)
摘    要:运用多种电化学方法,对现役桥梁进行了无损量化检测,分析了自然环境下的钢筋锈蚀特征,总结了自然环境对钢筋锈蚀率的影响规律,通过与前期实验室结果对比,揭示了自然环境与加速模拟环境的区别与联系.并对实测情况做了分级讨论.实桥测量结果表明:潮湿处的钢筋失重率最高达到33%,最低为18%;而干燥处钢筋失重率则分布在8%--15%之间.实测结果还表明:涂刷了防水层的箱梁及护栏,有助于保护混凝土内部配筋,能有效降低内部配筋的腐蚀速率,其失重率仅为4%~8%.承载重的桥台钢筋高于承载轻的护栏钢筋的锈蚀率.

关 键 词:自然环境  电化学检测  钢筋锈蚀  腐蚀速率  无损量化检测

Concrete Reinforcement Corrosion Characteristics and Grading Evaluation under Natural Conditions
Institution:HAO Baohong;ZENG Ding;SHENG Minhui;SONG Xiyang(Department of Mechanical Engineering,Beijing Institute of Petrochemical Technology;Research Institute of Highway Ministry of Transport; Beijing 100088,China)
Abstract:The paper,by using various electrochemical methods,conducts non-destructive quantitative testing towards currently-used bridges,analyzes reinforcement corrosion characteristics under natural environment,concludes the influencing rule of natural environment on reinforcement corrosion,and reveals differences and correlations between natural environment and accelerated simulation environment by contrasting with preliminary laboratory results.It also has a grading discussion towards the actual measurement conditions.The real bridge measurement results show that:weight loss ratio of reinforcement under humid environment can reach a maximum of 33% and a minimum of 18%;while weight loss ratio of reinforcement under dry environment falls between 8%~15%.The actual measurement results also show that:box girder and guard bar coated with waterproof layer help to protect reinforcing bars inside the concrete and effectively reduce the corrosion rate inside reinforcing bars with weight loss ratio around 4%~8%.In addition,the corrosion rate of bridge abutment reinforcement with heavier load-bearing is higher than that of guard bar reinforcement with lighter load-bearing.It contrasts the precision of two testing methods and comes to a conclusion that testing precision of linear polarization method is higher than that of impulse current method.
Keywords:natural environment  electrochemical testing  reinforcement corrosion  corrosion rate  non-destructive quantitative testing
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号