摘    要:分析了上海明珠线一期工程接触网防雷接地系统的效果及该线车辆遭受雷击的原因,认为地铁车辆的防雷与接触网系统的防雷必须密切配合,提出了城市轨道交通系统防雷的概念,并提出了加强改进接触网防雷接地系统的建议。

关 键 词:地铁  接触网  防雷接地系统  改进

OCS Lightning Protection Earthing System in First Phase of Shanghai Pearl Line
PENG Daming.OCS Lightning Protection Earthing System in First Phase of Shanghai Pearl Line[J].Electric Railway,2004(2):41-42.
Authors:PENG Daming
Institution:PENG Daming
Abstract:Analyses the effect of lightning protection earthing system in first phase of shanghai pearl line and the reason why some vehicles on the line suffered with lightning stroke, it concludes that the lightning protection system of vehicle shall closely co-ordinate with that of OCS, it raises the concept of lightning protection for urban mass transit system and proposes to strengthen and improve lightning protection earthing system of OCS.