首页 | 本学科首页   官方微博 | 高级检索  
     检索      

北京地铁5号线地下线减振措施现场测试与分析
引用本文:李克飞,刘维宁,孙晓静,丁德云,袁扬.北京地铁5号线地下线减振措施现场测试与分析[J].铁道学报,2011,33(4):112-118.
作者姓名:李克飞  刘维宁  孙晓静  丁德云  袁扬
作者单位:北京交通大学,土木建筑工程学院,北京,100044
基金项目:国家自然科学基金重点资助项目,北京交通大学优秀博士生科技创新基金
摘    要:为满足沿途多处敏感点的环境振动要求,北京地铁5号线采用了多种减振措施.其中地下线在一般减振、较高减振和特殊减振要求的地段分别安装了普通扣件、Ⅲ型轨道减振器扣件和钢弹簧浮置板轨道.采用高灵敏度加速度传感器,对北京地铁5号线地下线一般减振、较高减振和特殊减振地段进行了现场测试.在时域和频域内,比较了各测试断面钢轨、道床和隧...

关 键 词:地铁  减振措施  现场测试  频谱分析  振动加速度级

In-situ Test of Vibration Attenuation of Underground Line of Beijing Metro Line 5
LI Ke-fei,LIU Wei-ning,SUN Xiao-jing,DING De-yun,YUAN Yang.In-situ Test of Vibration Attenuation of Underground Line of Beijing Metro Line 5[J].Journal of the China railway Society,2011,33(4):112-118.
Authors:LI Ke-fei  LIU Wei-ning  SUN Xiao-jing  DING De-yun  YUAN Yang
Institution:(School of Civil Engineering,Beijing Jiaotong University,Beijing 100044,China)
Abstract:To meet the environmental vibration requirements at multiple sensitive points,kinds of vibration reduction measures are adopted for Beijing Metro Line 5.For the sections of the under ground line,ordinary fastenings are installed in sections under general vibration-reduction requirements.Rail Vibration Absorber Fastening Type Ⅲ in sections under high vibration-reduction requirements and the steel spring floating slab track(SSFST) in sections under special vibration-reduction requirements.In order to evaluate the practical effect of the above vibration reduction products,in-situ Metro-induced vibration tests of the underground lines have been performed with the highly sensitive acceleration sensors.The vertical vibration acceleration levels of rails,track beds and tunnel walls at different measuring cross-sections are compared in the time domain and frequency domain.The results show as follows:(1)Ordinary fastenings reduce Vibration transmission between rail and track bed effectively except for in the 20~80 Hz band,Rail Vibration Absorber Fastening Type Ⅲ reduces Vibration transmission between rail and track bed in all frequency bands to good effect,and SSFST is the best in Vibration attenuation,its performance being better in high-frequency bands than in low-frequency bands;(2)comparing the vibration acceleration levels of tunnel walls at different measuring cross-sections,the vibration attentuation effect of Rail Vibration Absorber Fastening Type Ⅲ is better than the ordinary fastening by 10~15 dB in the working-frequency band,and the effect of SSFST is better than that of the ordinary fastening by 10~25 dB in the working-frequency band and is obviously better than that of Rail Vibration Absorber Fastening Type Ⅲ in the 20~50 Hz and 80~200 Hz bands.
Keywords:metro  vibration mitigation measures  in-situ test  spectrums analysis  vibration acceleration level
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号