S7OOK型道岔灰显故障及改进措施
引用本文:李文雄,刘文提,王文志.S7OOK型道岔灰显故障及改进措施[J].都市快轨交通,2008,21(6):89--90.
作者姓名:李文雄  刘文提  王文志
作者单位:深圳市地铁有限公司,深圳,518040
摘    要:通过分析S700K型道岔发生灰显故障的各种原因,提出相应的改进措施。采用冗余技术,解决道岔速动开关和安全开关接点接触不良的问题,消除道岔灰显故障,减少对运营的影响。

关 键 词:S700K型道岔  灰显故障  开关接点
修稿时间:2013/12/6 0:00:00

S700K Point Switch Displayed Grey Fault and Corresponding Improvement
Li Wenxiong,Liu Wenti,Wang Wenzhi.S700K Point Switch Displayed Grey Fault and Corresponding Improvement[J].Urban Rapid Rail Transit,2008,21(6):89--90.
Authors:Li Wenxiong  Liu Wenti  Wang Wenzhi
Abstract:Through analyzing various reasons for S700K point switch displaying grey fault, the authors performed corresponding improvement by adopting redundant technology to solve the problem of bad contact between position switch and cut-off switch, and finally to eliminate the point switch displaying grey fault and reduce its impact on normal operation.
Keywords:S700K point switch  grey fault display  switch contact