引用本文:米永刚.厂房大体积混凝土温度应力分析[J].港工技术,2010,47(2):30-31,38.
作者姓名:米永刚
作者单位:西京学院工程技术系,陕西西安,710123
摘    要:由水泥水化过程中释放的水化热引起的温度变化和混凝土收缩产生的温度应力,是大体积混凝土产生裂缝的主要原因。结合某工程无损检测厂房,对大体积混凝土温度进行预测与实测,从而计算温度应力,得出要保证该工程混凝土不产生裂缝,需保证混凝土内外温差小于12℃的结论。

关 键 词:大体积混凝土  水化热  温度裂缝  温度应力

Analysis on Mass Concrete Thermal Stress of Plant
Mi Yonggang.Analysis on Mass Concrete Thermal Stress of Plant[J].Port Engineering Technology,2010,47(2):30-31,38.
Authors:Mi Yonggang
Institution:Mi Yonggang (Xijing Institute of Engineering Technology Department, Xi'an Shanxi 710123, China)
Abstract:The temperature change caused by the hydration heat released from the cement hydration process and concrete shrinkage resulting from thermal stress cracks are the main reason of the large volume of concrete cracking. Combining with the actual prediction and measurement for mass concrete temperature of non-destructive plant testing of some project, the temperature stress was calculated. The conclusion is that the temperature difference inside and outside should be kept at 12 ℃ or less in order to avoid the project concrete cracking.
Keywords:mass concrete  hydration heat  temperature cracks  thermal stress
本文献已被 CNKI 维普 万方数据 等数据库收录!