某船应急消防泵舱检查发现问题处理
引用本文:于志强.某船应急消防泵舱检查发现问题处理[J].中国修船,2014(6):4-5.
作者姓名:于志强
作者单位:中国船级社秦皇岛分社,河北秦皇岛066000
摘    要:应急消防泵舱与A类机器处所相邻,2个处所公用的舱壁应隔热至相当于控制站所要求的结构防火标准,然而在船级社检验和港口国检查时,发现两个处所结构防火存在较多缺陷。文章通过一则应急消防泵舱结构防火缺陷解决案例的介绍,希望给予验船师和船厂工作人员技术提示,避免类似问题发生。

关 键 词:应急消防泵舱  A-60绝缘泄放管  结构防火缺陷

Fault discovery and treatment during inspection of the marine emergency fire pump room
Abstract:During inspection from classification society and the port administration,several defects were discovered on structural fire-proof wall shared by the emergency fire pump room and the place for A-type machines,which demands a structural fire proof standard for heat-proof equal to a control station. In this paper,the technical indicator is given to the ship surveyor and workers to avoid some similar problems through a case of solving defect on structural fire-proof of emergency fire pump room..
Keywords:emergency fire pump room  A-60 insulation drain pipe  structural fire-proof defect