首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Objective To establish a flow-injection chemiluminescence method for the determination of doxorubicin, epirubicin and mitoxantrone and study its reaction mechanism. Methods In alkaline medium, chemiluminescence of luminol-potassium permanganate system could be inhibited obviously by anthracycline antibiotics. Combined with flow-injection technique, a new chemiluminescence method for determining the anthracycline antibiotics was set up. The chemiluminescence mechanism of the luminol-potassium permanganate system was also discussed. Results Under optimal conditions, the good linear ranges of doxorubicin, epirubicin and mitoxantrone were 5.0×10-9-1.0×10-6g/mL, 1.0×10-9-1.0×10-5g/mL and 3×10-9-1.0×10-6g/mL, respectively. The detection limits of doxorubicin, epirubicin and mitoxantrone were 3.0×10-9g/mL, 5.0×10-8g/mL and 2.0×10-9g/mL, respectively. During eleven repeated inter-day and intra-day precision tests of 1.0×10-6g/mL samples, the relative standard deviations corresponded to reference values of 3.0%, 2.8% and 2.1%. Conclusion The developed method is sensitive, accurate, rapid and of low cost. It can be applied to determine doxorubicin hydrochloride, epirubicin hydrochloride and mitoxantrone hydrochloride in injection preparations.  相似文献   

2.
Objective To develop a rapid, simple and sensitive chemiluminescence method for the determination of three β-blockers (bisoprolol, atenolol and propranolol). Methods The chemiluminescence of cerium (Ⅳ)-sulfite system was obviously sensitized by adding anyone of three β-blockers in acid media. A new chemiluminescence method was set up by combining with flow-injection technique and used to determine the three β-blockers. Results Good linear ranges were obtained at the concentrations of 2.0×10-7g/mL-4.0×10-5g/mL, 1.0×10-7g/mL-3.0×10-5g/mL and 7.0×10-7g/mL-1.0×10-5g/mL, respectively, with the detection limits of 5.0×10-8g/mL, 7.0×10-8g/mL and 5.0×10-8g/mL (S/N=3), respectively, and the relative standard deviations for 11 times consecutive injections of 1.0×10-6g/mL bisoprolol, atenolol and propranolol were 3.57%, 2.21% and 2.26%, respectively. Conclusion The developed method is sensitive, accurate, rapid and of low cost. And it can be applied to determine bisoprolol, atenolol and propranolol in pharmaceutical preparations.  相似文献   

3.
目的建立快速、准确测定对乙酰氨基酚的流动注射化学发光新方法。方法酸性条件下,KMnO_4可氧化钙指示剂产生化学发光,罗丹明B对此发光有较强的增敏,对乙酰氨基酚的存在抑制体系发光,基于此结合流动注射技术建立了一种新的测定对乙酰氨基酚含量的化学发光法。结果在优化的实验条件下,在5.0×10-7-1.0×10-5g/mL范围内,对乙酰氨基酚的质量浓度与化学发光信号的降低值有较好的线性关系,检出限(S/N=3)为7.0×10-8g/mL,对1.0×10-6g/mL对乙酰氨基酚进行11次平行测定,其相对标准偏差为2.2%。结论本方法简便、快速、准确,用于片剂中对乙酰氨基酚含量的测定,得到较满意的结果。  相似文献   

4.
The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CPL)and hydrochlorothiazide(HCT).The stoppe  相似文献   

5.
奋乃静药物的流动注射化学发光测定方法的建立   总被引:5,自引:0,他引:5  
目的建立快速测定奋乃静的流动注射化学发光新方法。方法在硝酸介质中,奋乃静能被硫酸铈氧化生成发光物质奋乃静砜,从而产生化学发光。基于此,建立了奋乃静的流动注射化学发光分析方法。结果在优化的实验条件下,不用任何发光增敏剂,奋乃静在1.0×10-7-7.0×10-5g/mL范围内与化学发光强度呈良好的线性关系,检出限(3σ)为8.0×10-8g/mL,对1.0×10-6g/mL的奋乃静进行了11次平行测定,其相对标准偏差为1.8%。结论本方法简便、快速、准确、灵敏度高、线形范围宽,应用于奋乃静片剂分析,并与药典方法进行对照,结果满意。  相似文献   

6.
目的 建立一种快速、准确、高灵敏度的检测含巯基药物的化学发光分析方法.方法 在硫酸酸性介质条件下,高锰酸钾可与乙二醛产生化学发光,而含巯基药物对该化学发光有显著的增强作用,基于此现象建立了流动注射化学发光分析法测定含巯基药物的新方法.结果 实验对影响化学发光的可能因素和参数进行了优化,在优化的条件下,甲巯咪唑、卡托普利和乙酰半胱氨酸分别在1.0×10~(-8)~5.0×10~(-6)、7.0×10~(-8)~1.0×10~(-6)和3.0×10~(-8)~1.0×10~(-6)g/mL浓度范围内与相对化学发光强度成良好的线性关系,检测限分别为1.0、3.9、3.7ng/mL.结论 本方法已成功应用于3种含巯基药物制剂的含量测定,与药典方法比较,结果满意.  相似文献   

7.
阐述了几种消毒方式的特性及其应用前景,通过对比臭氧,ClO2,微波,KMnO4及紫外线的消毒效果,确定了取代液氯消毒饮水的最佳方案.影响消毒剂效果的主要因素有温度、pH值及作用时间.消毒剂浓度与作用时间的关系可用ct(mg*min/L)值来表示,代表消毒剂的杀菌能力,对大肠杆菌,当pH为6~7时,臭氧、ClO2、氯的ct值分别为0.02,0.40~0.75,0.034~0.050.升高温度会加强消毒剂的灭菌效果,要保持原来的消毒效果就需要延长作用时间或增大消毒剂的剂量.  相似文献   

8.
A novel electrogenerated chemiluminescence (ECL) sensor for the determination of metoclopramide was developed by employing ruthenium complex as an ECL signal producer and an ordered mesoporous carbon (OMC) material as modified material. The ECL sensor was fabricated by adsorption ruthenium complex into a mixture of OMC and Nafion, which showed good electrochemical and ECL behaviors. It was found that the ECL intensity of the sensor fabricated was greatly enhanced in the presence of metoclopramide. Based on this finding, a highly sensitive and reproducible ECL method was developed for the determination of metoclopramide. The result showed that the ECL intensity was linear with the concentration of metoclopramide in the range from 1.0×10-10 to 5.0×10-7M and the detection limit was 3×10-11M. The ECL sensor exhibited a long-term stability and a fine reproducibility with relative standard deviation of 1.0 % for 1.0×10-10M metoclopramide in 18 continuous determinations. The developed method has been applied to the determination of metoclopramide in tablet samples with satisfactory results.  相似文献   

9.
流动注射-化学发光法测定阿昔洛韦和更昔洛韦   总被引:2,自引:0,他引:2  
目的确定以Ce(IV)-罗丹明B体系测定制剂中阿昔洛韦和更昔洛韦的流动注射-化学发光(FI-CL)分析方法。方法硫酸介质中Ce(IV)与阿昔洛韦/更昔洛韦发生氧化-还原反应而产生化学发光,罗丹明B可显著增强其发光信号,且增敏效果与阿昔洛韦/更昔洛韦浓度呈一定的线性关系。据此,建立了测定注射剂中阿昔洛韦和更昔洛韦的流动注射-化学发光新方法。结果阿昔洛韦在3.0×10-5g/L-7.0×10-2g/L范围内呈线性关系,检出限为1.56×10-5g/L;更昔洛韦在5.0×10-5g/L-7.0×10-2g/L范围内呈线性关系,检出限为2.35×10-5g/L。通过对质量浓度为1.0×10-3g/L的阿昔洛韦和更昔洛韦分别进行的11次平行测定,其相对标准偏差(RSD)分别为2.08%和2.83%。结论该方法线性范围宽、灵敏度高,简便快速,也是目前首次采用流动注射-化学发光法对更昔洛韦含量的测定。  相似文献   

10.
目的建立一种简单快速测定氢溴酸加兰他敏和力可拉敏的流动注射化学发光方法。方法在碱性条件下,加兰他敏与力可拉敏对鲁米诺-铁氰化钾发光体系有明显的抑制作用,且抑制效果与药物浓度呈线性关系。据此,建立了氢溴酸加兰他敏和力可拉敏的流动注射化学发光分析方法,并采用单因素优化方法对可能的影响分析方法的因素进行了优化。结果在优化条件下,加兰他敏和力可拉敏的线性范围分别为5×10-3~10mg/L和5×10-2~10mg/L;检出限分别为0.53μg/L和2.60μg/L。结论流动注射化学发光方法可以用于氢溴酸加兰他敏和力可拉敏药物制剂和生物样品的含量分析。  相似文献   

11.
高峰 《黑龙江交通科技》2004,27(10):41-41,43
介绍了汽车燃油喷射系统的分类与维修  相似文献   

12.
发动机二次空气喷射系统是一种新型的排气净化装置.它利用空气泵将新鲜空气经空气喷管喷入排气管或催化转化器.使排气中的CO和HC进一步氧化或燃烧成为二氧化碳(CO2)和水(H2O)。通过探讨二次空气喷射系统的结构原理、故障现象,掌握二次空气喷射系统的检测与维修。  相似文献   

13.
本文首先分析多品种流交通网络的特性,在借鉴Ford-Fulkerson算法的基础上构造了求多品种问题最大流的基于多品种流的Ford-Fulkerson算法。然后分析了多品种流交通网络对特定品种在结点上的流量有要求的几种情况,并设计了这几种情况下交通网络求最大流的算法。在实际交通网络中多品种流问题普遍存在,对特定结点的品种的流量有要求的多品种问题更是不胜枚举,本文的算法为解决实际问题提供了应用基础。  相似文献   

14.
A novel high performance liquid chromatographic method was developed for the determination of 4-O- methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation. Plasma samples were treated by one-fold volume of methanol and acetoni  相似文献   

15.
结构非线性机翼的超音速和高超音速颤振   总被引:3,自引:1,他引:3  
为探讨超音速、高超音速流中二元机翼的气动弹性特性,基于活塞理论计算了作用在翼面上的气动力,运用能量方法建立了系统的运动微分方程,采用Hopf分叉理论确定了系统的临界颤振速度,并考查了系统参数对临界颤振速度的影响;采用等效线性化和数值积分法研究了具有立方非线性刚度系统的极限环响应,二者结果一致.结果表明,在一定的(无量纲)速度范围内(9.48相似文献   

16.
在道路系统中,交叉口和公交停靠站附近常出现局部交通堵塞,是干扰城市交通畅通的主要瓶颈.考虑交叉口和公交停靠站的组合配置情景,基于元胞自动机模型,在开放边界条件下对双车道混合交通流的车辆换道和停靠行为进行细化,模拟研究需求变化和公交比例对整个交通系统的影响.仿真结果表明,对于不同的公交车比例,存在一个临界流入率,该临界值随着公交车比例的增加而逐渐降低.在临界值以内,车流属于自由流,流量随着流入率的增大而升高,而在临界值以外,流量达到饱和状态,不再随流入率增大而升高.在交通高峰期,信号交叉口上游排队会影响公交停靠站附近车辆运行.因此,根据交通需求设立合适的车站位置和信号灯周期是非常必要的.  相似文献   

17.
ANSYS软件在有垂直防渗墙的堤坝及地基渗流计算中的应用   总被引:4,自引:0,他引:4  
鉴于渗流场与温度场微分控制方程的可比拟性,根据渗流场基本方程及定解条件,运用ANSYS软件中"生死"单元技术及网格自适应功能,对具有垂直防渗墙的堤坝及地基的复杂渗流场问题进行计算分析.计算结果表明,该方法可以有效地计算分析复杂边界、多种介质的渗流场.  相似文献   

18.
目的 通过鞘内给氧与高压氧对颅脑损伤患者神经功能恢复的情况对比研究 ,探讨鞘内给氧对颅脑损伤患者神经功能障碍的治疗作用及其机制。方法 选择 15 0例颅脑损伤患者 ,随机分为鞘内给氧组、高压氧治疗组和鞘内注入过滤空气组 ,分别施行鞘内注入氧气、高压氧治疗及鞘内注入过滤空气 ,观察患者神经功能的改变 ,并检测脑脊液中超氧化物歧化酶 (SOD)、丙二醛 (MDA)和一氧化氮 (NO)水平的变化。结果 鞘内给氧组患者神经功能得到明显改善 ,且脑脊液中SOD、NO水平增高和MDA水平降低均较高压氧组明显。结论 鞘内给氧可以促进颅脑损伤患者神经功能障碍的改善 ,优于高压氧 ,且简便易行  相似文献   

19.
与车辆跟驰理论统一的一维交通流动力模型研究   总被引:2,自引:0,他引:2  
从交通流的连续性假设开始将交通流中的每一个参数(包括交通压力)都在流体流中 找到了恰当的比拟.通过理论推导,得出了类似一维可压缩理想流体流动的交通流连续性方 程、欧拉微分方程和动量方程.并从一维定常交通流的分析研究中,得出了交通压力的数学表 达式.从而得出了由连续性方程、欧拉微分方程、交通压力表达式和状态方程构成的一维交通 流动力模型,论证了该模型与车辆跟驰理论是统一的.  相似文献   

20.
车路通讯技术的发展为驾驶员提供当前和预测的交通状态信息创造了条件.本文考虑驾驶员的预测性及驾驶员群体对交通信息认知的异质性,建立了新的宏观交通流动力学模型.基于线性稳定性理论,获得了新模型的稳定性条件;通过仿真算例,分析了模型参数对交通流稳定性的影响.结果表明,驾驶员的预测时间、记忆时间、最优记忆流量差权重系数、驾驶员类型比例和记忆时间差异对交通流稳定性存在显著影响;而增大预测时间步长、记忆时间步长、权重系数和认知强度系数都可以有效增强交通流的稳定性;但交通信息认知差异增大却会破坏交通流稳定性.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号