无crowbar电路的双馈风电变流系统故障穿越设计
引用本文:黄中. 无crowbar电路的双馈风电变流系统故障穿越设计[J]. 船电技术, 2019, 39(5): 10-13
作者姓名:黄中
作者单位:武汉船用电力推进装置研究所,武汉,430064
摘    要:随着电网技术的发展,对风力发电系统的故障穿越能力提出更高的要求。本文提出了一种基于无crowbar电路的双馈风电变流器系统实现故障电压穿越的方法和策略,并通过仿真验证了其合理性和可行性,对项目设计和工程化应用有较大的借鉴意义。

关 键 词:故障电压穿越  双馈风电变流器  crowbar电路

Fault Traversal Design of Doubly-Fed Wind Power Converter System Without Crowbar Circuit
Huang Zhong. Fault Traversal Design of Doubly-Fed Wind Power Converter System Without Crowbar Circuit[J]. Marine Electric & Electronic Technology, 2019, 39(5): 10-13
Authors:Huang Zhong
Affiliation:(Wuhan Institute of Marine Electric Propulsion, Wuhan 430064, China)
Abstract:With the development of power grid technology, higher requirements are placed on the fault traversal capability of wind power generation systems. This paper proposes a method and strategy for fault voltage traversal which is based on a doubly-fed wind power converter system without crowbar circuit, and its rationality and feasibility are verified by simulation, which has great reference significance for project design and engineering application.
Keywords:fault voltage ride through  doubly-fed wind power converter  crowbar circuit