Study on fast calibration of a ULA's gain and phase error
引用本文:ZHU Guang-ping,SUN Hui,ZHANG Ming-hui.Study on fast calibration of a ULA's gain and phase error[J].船舶与海洋工程学报,2007,6(2):64-69.
作者姓名:ZHU Guang-ping  SUN Hui  ZHANG Ming-hui
作者单位:College of Underwater Acoustic Engineering, Harbin Engineering University, Harbin 150001, China
摘    要:Array calibration is important in engineering practice. In this paper, fast calibration methods for a ULA's gain and phase errors both in far and near fields are proposed. In the far field, using a single sound source without exact orientation, this method horizontally rotates the array exactly once, performs eigen value decomposition for the covariance matrix of received data, then computes the gain and phase error according to the formulas. In the near field, using the same single sound source, it is necessary to rotate the array horizontally at most three times, build equations according to geometric relations, then solve them. Using the formula proposed in this paper, spherical waves are modified into plane waves. Then eigen values decomposition is performed. These two calibration methods were shown to be valid by simulation and are fast, accurate and easy to use. Finally, an analysis of factors influencing estimation precision is given.

关 键 词:单声源  增益  相位误差  艾根数值分解  快速定标法  声纳
文章编号:1671-9433(2007)02-0064-06
收稿时间:22 March 2007
修稿时间:2007-03-22

Study on fast calibration of a ULA’s gain and phase error
Zhu Guang-ping,Sun Hui,Zhang Ming-hui.Study on fast calibration of a ULA’s gain and phase error[J].Journal of Marine Science and Application,2007,6(2):64-69.
Authors:Zhu Guang-ping  Sun Hui  Zhang Ming-hui
Institution:(1) College of Underwater Acoustic Engineering, Harbin Engineering University, Harbin, 150001, China
Abstract:Array calibration is important in engineering practice. In this paper, fast calibration methods for a ULA's gain and phase errors both in far and near fields are proposed. In the far field, using a single sound source without exact orientation, this method horizontally rotates the array exactly once, performs eigen value decomposition for the covariance matrix of received data, then computes the gain and phase error according to the formulas. In the near field, using the same single sound source, it is necessary to rotate the array horizontally at most three times, build equations according to geometric relations, then solve them. Using the formula proposed in this paper, spherical waves are modified into plane waves.Then eigen values decomposition is performed. These two calibration methods were shown to be valid by simulation and are fast, accurate and easy to use. Finally, an analysis of factors influencing estimation precision is given.
Keywords:ULA  single sound source  gain and phase error  eigen values decomposition
本文献已被 维普 万方数据 SpringerLink 等数据库收录!