对高土壤电阻率地区牵引变电所接地技术的分析
引用本文:林东雄.对高土壤电阻率地区牵引变电所接地技术的分析[J].铁道技术监督,2010,38(10):29-32.
作者姓名:林东雄
作者单位:福州市城市地铁有限责任公司,福建福州350001
摘    要:从接地的实质出发,论述短路电流是接地电阻的控制因素。从土壤湿度、土壤温度、土壤结构类型等3个方面分析土壤电阻率对接地电阻的影响,提出高土壤电阻率地区变电所降阻措施,以及接地网设计的一些方法。

关 键 词:牵引变电所  接地    电阻率  影响

Analyzing the Grounding Technology of Traction Substation in High Soil Resistivity Areas
Lin Dongxiong.Analyzing the Grounding Technology of Traction Substation in High Soil Resistivity Areas[J].Railway Quality Control,2010,38(10):29-32.
Authors:Lin Dongxiong
Institution:Lin Dongxiong
Abstract:Starting from the essence of grounding, the author analyses that the short circuit current is the controlling factor of grounding resistance. The author analyses factors of soil resistivity to the ground resistance: soil moisture, soil temperature, soil structure types. The author puts forward measures of reducing ground resistance of substation in the high soil resistivity area and some of the ways of grounding grid design.
Keywords:Traction Substation  Grounding  Soil  Resistivity  Influence