摘    要:为研究不同条件下架空线路耐张线夹温度分布情况,构建了基于耐张线夹简化结构的有限元模型,并在600 A工频交流电流和不同接触电阻比的条件下,进行了耐张线夹电磁-热耦合有限元仿真,最终得到耐张线夹的三维温度场分布. 仿真结果显示:在正常情况下,耐张线夹引流板处的温度最低;在线夹不同部位接触电阻增大的情况下,引流板处接触电阻的增大对线夹整体温度升高的影响最大,而线夹本体压接处接触电阻的增大对线夹温升影响最小,同时线夹温度升高也会制约架空线路导线载流量. 最后通过线夹电阻测量试验和温升试验验证仿真的准确性,误差约为2.3%. 

关 键 词:架空线路    耐张线夹    温度场分布    有限元仿真    电磁-热耦合分析    接触电阻
收稿时间:2018-07-19

Simulation Analysis and Verification on Three-Dimensional Temperature Field of Strain Clamps for Overhead Lines
DONG Xuanchang,QU Fengrui,LI Yanfei,WANG Yiqing.Simulation Analysis and Verification on Three-Dimensional Temperature Field of Strain Clamps for Overhead Lines[J].Journal of Southwest Jiaotong University,2019,54(5):997-1004.
Authors:DONG Xuanchang  QU Fengrui  LI Yanfei  WANG Yiqing
Abstract:In order to study the temperature distribution of the strain clamps of overhead lines under different conditions, the finite element model based on the simplified structure of the strain clamp was build, and under the conditions of 600 A power frequency alternating current and different contact resistance ratios, the electromagnetic-thermal coupling finite element simulation analysis of the strain clamp was carried out, and the three-dimensional temperature field distribution of the strain clamp was finally obtained. The simulation results show that under normal conditions, the temperature of the conductive plate of the strain clamp is the lowest. When the contact resistance at different parts of the clamp increases, the increase of contact resistance at the conductive plate has the greatest effect on the overall temperature rise of the clamp, whereas the increase of the contact resistance at the crimp connection of the clamp body has the least effect. Meanwhile the temperature of the clamp will also limit the current carrying capacity of overhead lines. Finally the accuracy of the simulation was verified through the clamp resistance test and temperature rise test, and the error is about 2.3%. 
Keywords:
本文献已被 CNKI 等数据库收录!
点击此处可从《西南交通大学学报》浏览原始摘要信息
点击此处可从《西南交通大学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号