首页 | 本学科首页   官方微博 | 高级检索  
     

M10-25门机回转支承机构的故障诊断及维修技巧
引用本文:李伟,卢志刚. M10-25门机回转支承机构的故障诊断及维修技巧[J]. 港口装卸, 2003, 0(4): 25-27
作者姓名:李伟  卢志刚
作者单位:066000,河北省秦皇岛市东港路45号,秦皇岛新港港务总公司调度室
摘    要:M 10 - 2 5门机回转机构下支承轴承出现故障时 ,使门机回转时产生振动、异响和回转吃力等现象。水平滚轮与轨道的间隙过大、下支承壳体缺油或进水等是产生故障的主要原因 ,使用专用工具———振销器有助于顺利完成下支承的更换工作

关 键 词:门机  回转机构  故障诊断  维修技巧
修稿时间:2003-04-24

Fault Diagnosis and Maintenance Skill of the Slewing Support Mechanism in M10-25 Portal Crane
Li Wei Lu Zhi gang. Fault Diagnosis and Maintenance Skill of the Slewing Support Mechanism in M10-25 Portal Crane[J]. Port Operation, 2003, 0(4): 25-27
Authors:Li Wei Lu Zhi gang
Affiliation:Li Wei Lu Zhi gang
Abstract:If the lower support bearing of the slewing mechanism in M10-25 portal crane occurs failue, the protal crane occurs vibration, unusual sound and strenuous rotation during slewing.The over gap of horizontal roller with rail, lack of oil or water filling of the lower support shell are the main reasons of the failure.The replacement of the lower support can be completed smoothly by using special tool-pin vibrator
Keywords:portal crane  slewing mechanism  fault diagnosis  maintenance skill