Effect of Explosion in a Gas Pipeline Compartment of a Utility Tunnel on Neighboring Metro Tunnels北大核心CSCD
作者单位:1.Jiangsu Jianke Project Management Co.Ltd, Nanjing210019;2.Nanjing University of Science and Technology, Nanjing210094;
摘    要:In this paper the numerical simulation analysis of the effect of explosion in the gas pipeline compartment of a utility tunnel on neighboring metro tunnels was conducted using the software AUTODYN. The results show that the TNT equivalent in a fireproof partition with length of 200 m is 41.6 kg when the gas concentration in the gas pipeline compartment reaches 10%; the blast wave has much effect on the crown and arch waist of the round metro tunnel and it’s necessary to take some protective measures in both areas; when the surrounding soil is sand, the utili- ty tunnel is above the round metro tunnel and their alignments are in the same direction, the greater the vertical spacing between the utility tunnel and the metro tunnel, the smaller the effect of the blast wave on the metro tunnel; when the vertical spacing is 7.2 m, the maximum dynamic tensile stress is 1.86 MPa (including the static stress value of 1 MPa in the tunnel segment) and it is slightly smaller than the designed tensile strength of metro tunnel (about 1.89 MPa). The maximum vibration velocity and the maximum displacement meet the structural stability require- ments, so it is suggested the vertical spacing between the utility tunnel and metro tunnel shall not be less than 7.2 m. © 2018, Editorial Office of "Modern Tunnelling Technology". All right reserved.