首页 | 本学科首页   官方微博 | 高级检索  
     

改进的脉冲声管法(英文)
引用本文:孙亮,侯宏. 改进的脉冲声管法(英文)[J]. 船舶与海洋工程学报, 2013, 12(1): 122-125. DOI: 10.1007/s11804-013-1173-x
作者姓名:孙亮  侯宏
作者单位:College of Marine,Northwestern Polytechnical University
基金项目:Supported by the National Natural Science Foundation of China under Grant No. 11204242;China Postdoctoral Foundation under Grant No. 2011M501477
摘    要:Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method is presented in this short paper. This proposed study is significantly different from the conventional pulse tube method because of the capability for a single plane damped sine pulse wave to generate in the water-filled pulse tube with a regular waveform and short duration time of about 1ms. During the generation process of the pulse, an inverse filter principle was adopted to compensate the transducer response. The effect of the characteristics of tube termination can be eliminated through the generation process of the pulse. Reflection coefficient from a water/air interface was measured to verify the proposed method. When compared with the expected theoretical values, a relatively good agreement can be obtained in the low frequency range of 500-2 000 Hz.

关 键 词:pulse tube  damped sine pulse  water-air surface  water-filled pulse tube

An improved water-filled pulse tube method using time domain pulse separation method
Liang Sun,Hong Hou. An improved water-filled pulse tube method using time domain pulse separation method[J]. Journal of Marine Science and Application, 2013, 12(1): 122-125. DOI: 10.1007/s11804-013-1173-x
Authors:Liang Sun  Hong Hou
Affiliation:11173. College of Marine, Northwestern Polytechnical University, Xi’an, 710072, China
Abstract:Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method is presented in this short paper. This proposed study is significantly different from the conventional pulse tube method because of the capability for a single plane damped sine pulse wave to generate in the water-filled pulse tube with a regular waveform and short duration time of about 1ms. During the generation process of the pulse, an inverse filter principle was adopted to compensate the transducer response. The effect of the characteristics of tube termination can be eliminated through the generation process of the pulse. Reflection coefficient from a water/air interface was measured to verify the proposed method. When compared with the expected theoretical values, a relatively good agreement can be obtained in the low frequency range of 500–2 000 Hz.
Keywords:
本文献已被 CNKI SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号