首页 | 本学科首页   官方微博 | 高级检索  
     


Refrigeration Performance Analysis and Its Applicability of a New Metal Hydride Couple in Auto Air-conditioning
Authors:NI Jiu-jian  CHEN Jiang-ping  CHEN Zhi-jiu  QIN Feng  U Man-qi  YANG Ke
Abstract:With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple--LaNi4.61Mn0. 26Al0. 13/La0. 6Y0. 4Ni4.8Mn0.2 was selected by establishing calculation procedure and metal hydride selection model. The experimental results show that the refigeration cycle of the selected couple is good in the performance. The recovered waste heat and refrigeration power from exhaust gas of several kinds of automobile are calculated by waste-heat formula,coefficient RQ and COP. Refrigeration cycle of the new couple can satisfy the air-conditioning requirement of truck and car and is not enough in passenger car ,according to the respective cooling load.
Keywords:metal hydried  couple  refrigeration cycle  coefficient of performance (COP)
本文献已被 CNKI 维普 万方数据 等数据库收录!