摘    要:文章以印尼某燃煤电厂工程为背景,研究了取排水明渠的不同布置形式对温排水扩散趋势和取水口温升的影响。并对原设计方案进行优化,在取水温升满足设计要求的条件下使工程更为经济合理。可为类似工程提供参考。

关 键 词:明渠  取水温升  影响

Study on influence of intake open channel arrangement form on temperature rise of cooling water
LIU Hai-cheng,CHEN Han-bao.Study on influence of intake open channel arrangement form on temperature rise of cooling water[J].Journal of Waterway and Harbour,2011,32(5):317-320.
Authors:LIU Hai-cheng  CHEN Han-bao
Institution:(Tianjin Research Institute for Water Transport Engineering,Key Laboratory of Engineering Sediment, Ministry of Transport,Tianjin 300456,China)
Abstract:Based on the background of a coal-fired power plant project in Indonesia,the influence of intake open channel arrangement form on the temperature rise of cooling water was studied.Then the original design scheme was optimized in a more economical and rational way.That provides a reference for similar projects.