朔黄线线岔极限温度下定位器偏移超限的探讨
引用本文:温志萍.朔黄线线岔极限温度下定位器偏移超限的探讨[J].电气化铁道,2009(3):30-31,33.
作者姓名:温志萍
作者单位:朔黄铁路发展有限责任公司,河北,肃宁,062350
摘    要:针对朔黄线中间站最外侧渡线线岔的结构,分析了其存在的缺陷,提出了解决该类缺陷的2种可行性方案并进行了比较,利用既有结构消除了极限温度下定位器反向偏移超限的现象,在应用中取得了良好的效果。

关 键 词:中间站  线岔  定位器  偏移超限

Discussion on Over-limit Offset of Steady Arm with Over-crossings under Limit Temperature in Shuozhou-Huanghuagang Railway Lines
Wen Zhiping.Discussion on Over-limit Offset of Steady Arm with Over-crossings under Limit Temperature in Shuozhou-Huanghuagang Railway Lines[J].Electric Railway,2009(3):30-31,33.
Authors:Wen Zhiping
Abstract:On basis of the middle of points most lateral crossover line bifurcated structure of Shuo huang railway,analyzes the deficiencies of the structure,puts forward two feasible projects which deal with these defects,and compares between two feasible plans,by using of the original structure to overcome the localizers reverse migration transfinite phenomenon under the maximum and minimum temperature,and applies the improved projects into practice,achieves a good results.
Keywords:intermediate railway station  line bifurcated  localizer  migration transfinite  