首页 | 本学科首页   官方微博 | 高级检索  
     检索      

GCT/GTO阴极梳条修理的方法
引用本文:陈芳林,邹昌,程银华.GCT/GTO阴极梳条修理的方法[J].变流技术与电力牵引,2010(2).
作者姓名:陈芳林  邹昌  程银华
作者单位:株洲南车时代电气股份有限公司电力电子事业部;
摘    要:在分析GCT/GTO阴极结构的基础上,指出了阴极失效梳条的成因及其危害,就减少失效梳条带来的影响,介绍了阴极梳条修理方法和装置。实际生产的统计数据表明,修理梳条方法降低了GCT和GTO芯片废品率和生产成本。

关 键 词:GCT  GTO  阴极梳条  失效梳条  

Repair Approaches of Cathode Fingers for GCT/GTO
CHEN Fang-lin,ZOU Chang,CHENG Yin-hua.Repair Approaches of Cathode Fingers for GCT/GTO[J].Converter Technology & Electric Traction,2010(2).
Authors:CHEN Fang-lin  ZOU Chang  CHENG Yin-hua
Institution:Power Electronics Business Unit;Zhuzhou CSR Times Electric Co.;Ltd.;Zhuzhou;Hunan 412001;China
Abstract:Based on analyzing cathode structure of GCT/GTO, formations and damages of the failure cathode fingers are indicated.Furthermore, in order to minimize the influence caused by failure fingers, it introduces repair approaches and equipments of cathode fingers.The actual statistics of production data shows that the approaches can decrease reject rate and production cost of GCT and GTO.
Keywords:GCT  GTO  cathode finger  failure finger  
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号