摘    要:宝钢马迹山矿石中转港盐雾腐蚀严重,供电电网短路容量小,港内有大冲击负荷。针对上述特点,在港区无功功率补偿及谐波设计时,选用了热管自冷却技术的SVC装置,实际运行效果非常好。可为类似工程提供借鉴。

关 键 词:小容量电网  大冲击负荷  SVC装置  晶闸管热管自冷

Reactive Power Compensation and Harmonic Filtering Design of Baosteel Majishan Ore Transshipment Port
YAO Yu. Reactive Power Compensation and Harmonic Filtering Design of Baosteel Majishan Ore Transshipment Port[J]. China Harbour Engineering, 2010, 0(1): 37-38
Authors:YAO Yu
Affiliation:CCCC Third Harbour Consultants Co.;Ltd.;Shanghai 200032;China
Abstract:Salt-fog corrosion is serious in Baosteel Majishan ore transshipment port,and short-circuit capacity in the power network of the port is small,besides there are heavy impact loads in the port.In view of the aforesaid features,SVC equipment with the technique of heat pipe natural cooling is chosen in the design of reactive power compensation and harmonic filtering of the harbour area.The practical operating results are good.It can be a good reference for the similar engineering.
Keywords:lowpower utility  heavy impact load  SVC equipment  heat pipe natural cooling of thyristor  