首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Analysis of Numerical Results in High Temperature Congealment and Chemistry Non-equilibrium Flow Field
作者姓名:ZHENG Hong-tao  TAN Zhi-yong  SUN Hai-ou  ZHOU Chun-liang  LI Zhi-mingCollege of Power and Nuclear Engineering  Harbin Engineering University  Harbin  China
作者单位:ZHENG Hong-tao,TAN Zhi-yong,SUN Hai-ou,ZHOU Chun-liang,LI Zhi-mingCollege of Power and Nuclear Engineering,Harbin Engineering University,Harbin 150001,China
摘    要:Using the air plasma ignition technique, physicochemical process of burning can be accelerated; concentration limit ofretrofires both can be extended; reliability of retrofires and stability of burning can be improved. In this paper, using internalequivalent heat area in place of electric are that created Ohm heat, the flow fields of thermodynamic equilibrium chemistry con-gealment and chemistry non-equilibrium in the plasma generator were simulated. The influences of the inlet prerotation angleof air, the inlet total pressure of air and the airflow compression angle of spray nozzle on the temperature on the surface of elec-


Analysis of numerical results in high temperature congealment and chemistry non-equilibrium flow field
ZHENG Hong-tao,TAN Zhi-yong,SUN Hai-ou,ZHOU Chun-liang,LI Zhi-mingCollege of Power and Nuclear Engineering,Harbin Engineering University,Harbin ,China.Analysis of Numerical Results in High Temperature Congealment and Chemistry Non-equilibrium Flow Field[J].Journal of Marine Science and Application,2002,1(1):26-34.
Authors:Hong-tao Zheng  Zhi-yong Tan  Hai-ou Sun  Chun-liang Zhou  Zhi-ming Li
Institution:(1) College of Power and Nuclear Engineering, Harbin Engineering University, 150001 Harbin, China
Abstract:Using the air plasma ignition technique, physicochemical process of burning can be accelerated; concentration limit of retrofires both can be extended; reliability of retrofires and stability of burning can be improved. In this paper, using internal equivalent heat area in place of electric arc that created Ohm heat, the flow fields of thermodynamic equilibrium chemistry con-gealment and chemistry non- equilibrium in the plasma generator were simulated. The influences of the inlet prerotation angle of air, the inlet total pressure of air and the airflow compression angle of spray nozzle on the temperature on the surface' of electrode nearby the electrode spot and the average temperature of outlet of spray nozzle were contrasted and analyzed. Considering the chemistry non - equilibrium flow, the change of temperature on the surface of electrode after ablation of electrode was further studied. As a result, when the internal flow field of plasma generator was calculated, if the computation model of congeal-merit flow was used, although the parameter change rules were consistent with thase of chemistry non - equilibrium, the results had much difference with the chemistry non - equilibrium. So the results of the computation of congealment flow cannot be completely used in quantitative analysis.
Keywords:plasma generator  chemistry non - equilibrium  ignition technique  numerical calculation  