首页 | 本学科首页   官方微博 | 高级检索  
     检索      

关于测长防雷器件烧损原因分析及解决方案
引用本文:韩秋月,王军.关于测长防雷器件烧损原因分析及解决方案[J].铁路通信信号工程技术,2012,9(4):26-27.
作者姓名:韩秋月  王军
作者单位:1. 北京全路通信信号研究设计院有限公司,北京,100073
2. 北京铁路局石家庄电务段,石家庄,053000
摘    要:对电气化区段驼峰测长轨道电路室内分线盘防雷器件烧损进行分析并提出解决方案,方案实施后取得较好的效果。

关 键 词:驼峰  电气化  测长轨道电路  防雷

Causation Analysis and Solution to Burning of Lightning Protection Parts of Length Measurement Equipment
Han Qiuyue,Wang Jun.Causation Analysis and Solution to Burning of Lightning Protection Parts of Length Measurement Equipment[J].Railway Signalling & Communication Engineering,2012,9(4):26-27.
Authors:Han Qiuyue  Wang Jun
Institution:Han Qiuyue,Wang Jun
Abstract:The paper analyzes the burning of lightning protection parts on indoor distributing board of length measurement track circuit for hump yard in electrified section and presents the solution which obtains desirable results after implementation.
Keywords:hump  electrification  length measurement track circuit  lightning protection
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号