首页 | 本学科首页   官方微博 | 高级检索  
     

Punching Shear Behavior of RC Slab-Column Connections with Nonrectangular Columns
引用本文:刘文珽 黄承逵 张瑞鹤. Punching Shear Behavior of RC Slab-Column Connections with Nonrectangular Columns[J]. 西南交通大学学报(英文版), 2005, 13(1): 70-77
作者姓名:刘文珽 黄承逵 张瑞鹤
作者单位:[1]StateKeyLaboratoryofCoastalandOffshoreEngineering,DalianUniversityofTechnology,Dalian116024,China [2]LanzhouJundaMunicipalEngingeeringConsultingCompany,Ltd.,Lanzhou730030,China
摘    要:This paper present an experimental study on the RC slab-colunm connections with nonrectangular colunms, namely cross-shaped column, T-shaped column and L-shaped column. The punching shear deformation and strength characteristics of slab-column connections with nonrectangular columns under punching shear load are investigated. Nine specimens with the three kinds of nonrectangular columns and two reference specimens with square columns are tested. The tested ultimate loads, deformations, and failur emodes of specimens are presented and discussed. Test results reveal that the punching shear strength and ductility of the connections with nonrectangular columns are higher than those of the corresponding connections with square columns, and also prove that the application of nonrectangular columns to flat-plate structure was feasible. Based on the test results, one method of calculating punching shear strength of connections with nonrectangular columns is proposed, which conforms with the current design practice of China. The test results on the punching shear strength are compared with the predictions of the formulas proposed by codes of several different countrie; and the predictions given by ACI code and China code are found to be conservative as the reinforcement ratio is increased.

关 键 词:非直角柱 钢筋混凝土 冲压剪切 延伸性

Punching Shear Behavior of RC Slab-Column Connections with Nonrectangular Columns
Liu wenting,Huang Chengkui,Zhang Ruihe. Punching Shear Behavior of RC Slab-Column Connections with Nonrectangular Columns[J]. Journal of Southwest Jiaotong University, 2005, 13(1): 70-77
Authors:Liu wenting  Huang Chengkui  Zhang Ruihe
Abstract:This paper present an experimental study on the RC slab-column connections with nonrectangular columns, namely cross-shaped column, T-shaped column and L-shaped column. The punching shear deformation and strength characteristics of slab-column connections with nonrectangular columns under punching shear load are investigated. Nine specimens with the three kinds of nonrectangular columns and two reference specimens with square columns are tested. The tested ultimate loads, deformations, and failure modes of specimens are presented and discussed. Test results reveal that the punching shear strength and ductility of the connections with nonrectangular columns are higher than those of the corresponding connections with square columns, and also prove that the application of nonrectangular columns to flat-plate structure was feasible. Based on the test results, one method of calculating punching shear strength of connections with nonrectangular columns is proposed, which conforms with the current design practice of China. The test results on the punching shear strength are compared with the predictions of the formulas proposed by codes of several different countrie; and the predictions given by ACI code and China code are found to be conservative as the reinforcement ratio is increased.
Keywords:Nonrectangular columns  Reinforced concrete  Slab-column connections  Punching shear  Ductility
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号