首页 | 本学科首页   官方微博 | 高级检索  
     检索      

对客运专线ZPW-2000A轨道电路系统防雷问题的探讨
引用本文:刘锐冬.对客运专线ZPW-2000A轨道电路系统防雷问题的探讨[J].铁路通信信号工程技术,2012,9(5):70-72.
作者姓名:刘锐冬
作者单位:北京全路通信信号研究设计院有限公司,北京,100073
摘    要:简要介绍客运专线ZPW-2000A轨道电路系统的防雷设计,重点对雷害损坏客运专线ZPW-2000A轨道电路设备的原因进行技术探讨,并提出相应改进措施。

关 键 词:防雷  ZPW-2000A  轨道电路  单端接地  双端接地

Technical Discussion of Lightning Protection of ZPW-2000A Track Circuit System for DPL
Liu Ruidong.Technical Discussion of Lightning Protection of ZPW-2000A Track Circuit System for DPL[J].Railway Signalling & Communication Engineering,2012,9(5):70-72.
Authors:Liu Ruidong
Institution:Liu Ruidong
Abstract:The paper briefly describes the lightning protection design of the ZPW-2000A track circuit system for dedicated passenger lines (DPLs). While, it discusses especially and technically the causes of damaging ZPW-2000A track circuit equipment, and puts forward the improvement measures accordingly.
Keywords:lightning protection  ZPW-2000A  track circuit  single-end earthing  double-end earthing