Shipboard Fluid System Diagnostic Indicators Using Non-Intrusive Load Monitoring
Authors:GREGORY R. MITCHELL  ROBERT W. COX  JAMES PARIS   STEVEN B. LEEB
Affiliation:Massachusetts Institute of Technology;
MIT
Abstract:Field studies have demonstrated that it is possible to evaluate the state of many shipboard systems by analyzing the electrical power that is drawn by electromechanical actuators. This paper demonstrates how a device known as a non-intrusive load monitor (NILM) uses only electrical power data to detect several critical faults in shipboard fluid systems. Using the example of reverse-osmosis units installed aboard the US Coast Guard's Medium Endurance Cutters, it is shown that the NILM can provide ship's force with a highly reliable real-time system monitoring capability.