摘    要:介绍了25Hz电子相敏轨道电路叠加ZPW-2000A电码化的综合调整方法及调整中应特别注意的问题,同时对有关联锁试验进行说明。

关 键 词:相敏轨道电路  电码化  综合调整  联锁试验

Adjustment and Commissioning Test of Encoded Track Circuit within Station
Song Jianxin.Adjustment and Commissioning Test of Encoded Track Circuit within Station[J].Railway Signalling & Communication,2009,45(5):21-23.
Authors:Song Jianxin
Abstract:The synthesized adjustment approaches of overlapping 25Hz phase detecting track circuit and ZPW-2000A code circuit and considerations in this regard were introduced. At the same time, eorresponding interlocking testing was expounded.