首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 61 毫秒
1.
IntroductionStudies conducted by some researchers haveshown steel corrosion has significant influence onthe limited durability of reinforced concrete struc-tures[1,2]. Corrosion of steel creates a volume ex-pansion in reinforcing bars and causes extremelyhigh tensile stress in concrete, and this may lead tothe formation of cracks in the cover concrete due toits relatively low tensile strength.The cracks leadto a weakening bond and anchorage between rein-forcing steel and concrete, which direct…  相似文献   

2.
Introduction Concrete and reinforced concrete ( RC) havebecome the most widely used construction materials inthe world as they are easily acquired and lowerpriced. Normally, cover concrete acts as a physicalbarrier to the ingress of aggressive agents and …  相似文献   

3.
为研究无砟轨道混凝土在客、货车作用下的劣化规律,基于损伤力学概念,引入损伤变量对混凝土室内循环加载进行试验研究. 首先,建立钢轨-扣件-轨道板-CA砂浆层-底座板-地基有限元实体模型,获取试件试验等效应力水平,通过列车车速确定加载频率,然后确定合理的荷载组合模拟工况;其次,应用MTS加载系统对混凝土试件进行循环加载测试,利用无损检测系统测试了不同加载次数下混凝土的动弹性模量以及抗折强度;最后,将动弹性模量和抗折强度作为损伤变量,根据测试结果得到不同应力水平、加载频率作用对轨道板材料力学性能劣化规律的影响. 试验结果表明:在客货车荷载作用下,动弹性模量的损伤程度在加载200万次时约为抗折强度的损伤程度的2倍;应力水平一定时,加载频率越小,混凝土动弹性模量以及抗折强度的损伤程度越大,并且在10 Hz与15 Hz频率之间较明显;加载频率一定时,应力水平越大,混凝土动弹性模量以及抗折强度的损伤越严重,应力水平为0.7的混凝土在1 000次左右的加载循环加载下发生破坏;低速的客货车荷载会加快混凝土初期损伤,较高速度的客货车荷载会加速无砟轨道结构后期损伤的发展.   相似文献   

4.
从PEER数据库中选取7根钢筋混凝土柱在低周反复荷载作用下的试验数据,在分析了不同轴压比和配箍率下各试件的滞回特性、延性指标和割线刚度退化等的基础上,基于钢筋混凝土构件的Park-Ang双参数破坏准则,研究了构件损伤与耗能的关系、轴压比和配箍率对滞回耗能和损伤演化的影响。结果表明,轴压比较小和配箍率较高的试件,滞回曲线较为饱满,具有较好的延性性能;在一定范围内,增大轴压比或配箍率可以提高试件的屈服位移、屈服荷载和峰值荷载;加载前期,试件的损伤主要由位移首次超越引起,累积耗能对试件损伤影响相对较小,随着位移幅值的增大,累积耗能对试件损伤的贡献逐渐加大;配箍率相同的情况下,减小箍筋的间距对改善钢筋混凝土抗震性能有显著作用。  相似文献   

5.
采用拔出和梁式两种试验方法,对比分析了在不同受力状态下变形钢筋与活性粉末混凝土之间的黏结性能.研究表明:两种受力方式下的试件均有活性粉末混凝土劈裂、钢筋拔出与活性粉末混凝土劈裂共同发生、钢筋拔出3种破坏形式;钢筋在活性粉末混凝土中的黏结应力-滑移曲线都可分为4个阶段,但不同受力方式下每阶段特征略有差异;两种受力方式下,黏结强度都随钢纤维掺量的增加而增大,当钢纤维掺量由0%增加到2.0%时,拔出试验的黏结强度增长28.25%,而梁式试验的黏结强度增幅达到58.61%;当活性粉末混凝土中不掺加钢纤维时,梁式试验的黏结强度要小于拔出试验,但掺加钢纤维后,要大于拔出试验.  相似文献   

6.
为探明青海地区桥梁桩基在干湿-冻融循环条件下的腐蚀损伤特性, 依托德香高速公路工程, 在现场埋设钢筋和混凝土试件进行干湿-冻融循环1年, 采用室内试验将混凝土试件进行干湿-冻融循环225次, 对比分析了不同位置和不同循环时间条件下混凝土质量、抗侵蚀系数、相对动弹性模量、抗压强度、微观机理以及钢筋锈蚀率的变化规律; 采用数值仿真分析了未防护桩基20年内承载力变化规律, 并提出了高寒盐沼泽区桥梁桩基防护措施。研究结果表明: 随着试件埋设深度的增加, 现场桩基混凝土试件的抗侵蚀系数相关度增大, 最大值为0.93;随着时间的增加, 桩基混凝土试件的抗压强度最大损失率为38.20%, 埋深0.25 m处钢筋的面积锈蚀率最大, 为91%;表面涂抹环氧树脂可以有效减少钢筋锈蚀率, 桩基混凝土试件与钢筋的质量变化不明显; 干湿-冻融循环225次时, 桩基混凝土试件的边角处出现脱落, 四周出现裂纹, 但质量变化较小, 相对动弹性模量降低了39.10%, 抗侵蚀系数降低到0.51, 混凝土的抗压强度损失率为65.88%, 其内部因出现Friedel盐等膨胀性物质而趋于破坏; 随着剥落厚度和腐蚀深度的增加, 前8年桩基的承载力基本不变, 8年后其承载力逐步降低, 若不进行维护, 第20年桩基承载力降低34.45%;建议在桩基服役8年后, 要进行重点防护。   相似文献   

7.
采用预应力CFRP片材加固钢筋混凝土柱,可以提高柱的抗震性能.本文采用有限元分析软件ANSYS,对预应力CFRP片材加固钢筋混凝土柱的低周反复荷载试验过程进行了数值模拟分析,提出了分析同类问题的有限元算法,研究了预应力大小对预应力FRP片材加固钢筋混凝土柱抗震性能的影响,分析了预应力FRP片材加固钢筋混凝土柱的破坏机理.分析结果表明:随着FRP片材预应力度的增加,被加固柱的滞回曲线趋于饱满,滞回环的外包面积增大,延性增加,其耗能能力和抗震性能显著提高.  相似文献   

8.
为了研究碳纤维增强复合材料(CFRP)加固震损非延性钢筋混凝土(RC)框架抗震性能,制作并完成了1榀1/2缩尺两层两跨非延性RC框架子结构试件加固前后的拟静力试验. 将试件加载至峰值承载力,对采用外包CFRP法对震损节点处进行加固后的试件进行试验研究,获得了CFRP加固震损非延性RC框架的破坏形态与滞回曲线,分析了其刚度、强度、延性和耗能等抗震性能指标,并与完好结构进行对比. 分析结果表明:CFRP加固对提高震损非延性钢筋混凝土框架结构的最大水平承载力、初始刚度有限,对其耗能能力提升明显;加固结构的平均位移延性系数为2.81;当其最大层间位移角到达1/50时,加固结构依然具有较大的安全储备空间,加固后的震损非延性RC框架结构可以用于地震区.   相似文献   

9.
钢管混凝土结构节点的抗震性能的研究一直受到人们的重视,低周反复加载试验结果指出,加强环式节点滞回曲线饱满且稳定,但同时也发现,在节点域会出现鼓胀现象.为了解释这一现象,对加强环式节点进行了低周反复加载非线性模拟分析.分析内容包括节点的滞回耗能指标、节点域变形及节点域塑性扩展三部分.研究指出:(1)节点的滞回曲线饱满稳定,耗散系数都在2.0以上,表明节点整体延性很好;(2)腹板焊缝孔开孔过大,节点滞回曲线有不重合现象,可见腹板焊缝孔尺寸需要控制;(3)节点域柱壁有明显的变形,规律与滞回曲线相似,表明节点滞回曲线主要是由柱壁变形而非梁端塑性变形贡献的;(4)在反复荷载作用初期,环板就出现了贯穿的塑性带,而在相隔相当长的荷载循环之后,梁面上才有塑性出现.由于在反复荷载作用下,节点域发生了明显的变形,且在环板上形成贯穿的塑性带.  相似文献   

10.
The effects of length and location of the steel corrosion on the structural behavior and load capacity of reinforced concrete (RC) columns have been investigated. Results of the accelerated corrosion process and eccentric load test are presented in detail. Effects of the location of the partial length, the corrosion level within partial length and the asymmetrical deterioration of the concrete section on the mechanical behavior and load capacity of corroded RC columns are discussed. It is found that the mechanical behavior and load carrying capacity of corroded RC columns are simultaneously affected by the above mentioned factors. For the corroded RC columns with large eccentricity, a higher corrosion level in the tensile corroded length and a greater asymmetrical deterioration of the concrete section can result in less ductile behavior and larger load reduction of the column; while for the corroded RC columns with small eccentricity, the less ductile behavior and the larger load reduction of the column may result from the higher corrosion level in the compressive corroded length and the greater asymmetrical deterioration of the concrete section.  相似文献   

11.
系统研究了强腐后Q345钢表面形貌和腐蚀时间对其力学性能退化的影响;采用浓度36%工业盐酸在室温环境下快速腐蚀的方法,设计了腐蚀时间分别为0、1、2、4、8、12、24、48、72 h的9组钢试件;采用三维非接触激光扫描仪和扫描电镜扫描腐蚀钢,测量了最大蚀坑宽度、高度和腐蚀试件厚度,计算了最大蚀坑影响系数;开展了拉伸试验,结合扫描形貌与微观组织形态解释了强腐后Q345钢的力学性能退化机理;建立了浓度36%工业盐酸在室温环境强腐后Q345钢的腐蚀动力学曲线和本构关系模型,揭示了强腐后Q345钢的力学性能退化规律。研究结果表明:随着腐蚀时间的增加,Q345钢的腐蚀动力学曲线展示了腐蚀率的变化规律;腐蚀时间在1 h以内,最大蚀坑影响系数增大最为明显,钢的名义屈服强度、名义抗拉强度、名义弹性模量和伸长率退化较大,分别达到未腐蚀钢的3.00%、0.69%、1.99%和4.88%;当腐蚀时间超过12 h,最大蚀坑影响系数增加缓慢,钢的名义屈服强度、名义抗拉强度、名义弹性模量和伸长率退化较为缓慢,分别达到未腐蚀钢的7.58%、4.02%、10.27%和26.64%;随着最大蚀坑影响系数和腐蚀时间的增加,屈强比变化较小;在腐蚀试件的应力-应变本构关系曲线中,随着腐蚀时间的增加,钢材的屈服平台逐渐缩短甚至消失,钢材由延性破坏转变为脆性破坏。   相似文献   

12.
锈蚀RC梁抗弯承载力计算方法研究   总被引:1,自引:1,他引:0  
工程中钢筋混凝土梁纵向受力钢筋锈蚀情况复杂,梁上作用荷载形式多变. 为获取锈蚀RC (reinforced concrete)梁的抗弯承载能力,以锈蚀钢筋混凝土简支梁为研究对象,将锈蚀RC梁视为由混凝土和锈蚀底部纵筋组成的存在粘结-滑移的组合梁,依据混凝土与锈蚀钢筋之间的变形协调条件,给出了以挠度表达的锈蚀RC简支梁平衡微分方程;将平衡微分方程的齐次解作为单元形函数,推导出了锈蚀钢筋混凝土梁的单元刚度矩阵、等效节点荷载列阵以及每一荷载步锈蚀梁的内力计算公式;建立了能准确反应简支梁上荷载作用形式以及钢筋锈蚀状况的锈蚀RC梁抗弯承载力计算模型;最后通过17根锈蚀RC简支梁的试验数据对建议计算方法进行验证. 验证结果表明,抗弯承载力试验值与计算值之比的平均值为1.06,方差为0.012,二者吻合良好,该计算方法准确.   相似文献   

13.
为了研究钢筋粘结滑移对钢筋混凝土墩柱在地震荷载下的弹塑性滞回性能的影响,采用有限元OpenSEES对试验墩柱进行了有限元数值模拟,同时参数分析了在改变墩柱延性、钢筋屈服强度、混凝土的约束以及加载历程对粘结滑移曲率的影响。分析结果表明:考虑钢筋粘结滑移的模型能较好地反映滞回曲线的“捏拢”效应以及墩柱强度与刚度的退化作用,与实际结果模拟较好,可供钢筋混凝土墩柱数值模拟和地震反应分析参考。  相似文献   

14.
为了研究不同数量暗支撑对型钢混凝土剪力墙的抗震性能影响,选取4个剪跨比为1.75的矩形截面型钢混凝土剪力墙试件进行了低周反复荷载下的试验研究(其中1个为普通剪力墙对比试件,3个为工字钢暗支撑剪力墙试件),对比分析了不同数量暗支撑条件下型钢混凝土剪力墙试件的破坏特征、承载力、刚度、延性、滞回特性及耗能能力.试验研究表明:带暗支撑型钢混凝土剪力墙试件的裂缝细密且分布区域较大,塑性铰发展充分,滞回曲线饱满,耗能能力明显提高;带暗支撑型钢混凝土剪力墙试件的屈服荷载和极限荷载相比普通剪力墙分别提高了88.76%和91.97%,极限位移角提高26.67%,抗震能力比对比试件显著提高.   相似文献   

15.
为研究碳纤维增强复合材料CFRP对约束混凝土柱延性性能的影响,玻璃纤维增强复合材 料GFRP对约束混凝土柱的强度和延性的改善效果,以及高强度CFRP以外的其他材料的约束效 应,并分析它们在约束混凝土柱中的作用机理,通过对纤维增强复合材料FRP约束柱布置纵向、 环向位移传感器进行单轴压缩试验,由裂纹走向及破坏形态总结出了FRP约束柱的破坏过程,根 据荷载-应变曲线、荷载-位移曲线研究了FRP 约束混凝土圆柱的强度和延性性能。研究结果表 明:(1) CFRP 和GFRP 作为约束材料,都可以产生强的约束效应,提高约束混凝土的强度, CFRP、GFRP约束混凝土强度分别增加了29.2%和58.6%;(2) 强约束作用下,CFRP和GFRP约 束混凝土柱的强度和延性性能得到显著改善;(3) 由于单一FRP材料的线弹性性质,FRP约束混 凝土柱破坏时脆性特征明显;(4) 与CFRP相比,变形性能较好的GFRP能更好地改善混凝土柱 的延性性能,设置1 层GFRP相比1 层CFRP延性可提高61.9%,设置2 层GFRP相比2 层CFRP延 性可提高63.6%。  相似文献   

16.
鉴于大比例、高配筋混凝土梁粘纤维增强片材加固试验数据相对不足,完成了9根外贴碳纤维布或板加固实尺模型梁的受弯性能试验,以考察梁表面处理方式、加固前预载历史和加固片材类型对加固梁抗弯能力和破坏形态的影响.研究结果表明,梁面打磨不如凿毛处理时粘结牢靠,破坏形态为剥离;若能避免剥离,碳纤维布和板均有良好的加固效果;当碳纤维片材的轴向抗拉刚度相等时,贴布的加固效果优于贴板;加固时梁上既有荷载越小,则加固效果越好;大梁比小梁更易出现界面应力超限,更易剥离.基于《碳纤维片材加固混凝土结构技术规程》的基本假定,考虑既有荷载的影响,对试验梁的开裂弯矩、屈服弯矩和极限弯矩进行了计算,其结果与实测值吻合较好.  相似文献   

17.
本文介绍五个钢筋混凝土框架边节点试件在低周反复荷载下的试验结 果。时边节点的杭剪强度进行了讨论。在与混凝土结构设计规范送审稿 中框架节点杭剪强度计算公式对比的基础上,提出了框架边节点杭剪强 度计算建议,衬比试验结果,符合较好。   相似文献   

18.
三峡库区酸沉降引起的桥梁腐蚀效应   总被引:1,自引:0,他引:1  
通过对三峡库区自然环境条件研究表明,三峡库区酸沉降频,库区的一些环境条件(尤其是湿度)对桥梁等建筑物的腐蚀效应有加速的作用,库区桥梁中钢材最容易受到腐蚀,其腐蚀可分为一般砼中钢筋的腐蚀、预应力砼中钢筋的腐蚀及其它钢铁材料的腐蚀,此外,桥梁中的砼材料也会与环境的酸性介质发生腐蚀.  相似文献   

19.
通过对三峡库区自然环境条件研究表明,三峡库区酸沉降频,库区的一些环境条件(尤其是湿度)对桥梁等建筑物的腐蚀效应有加速的作用,库区桥梁中钢材最容易受到腐蚀,其腐蚀可分为一般砼中钢筋的腐蚀、预应力砼中钢筋的腐蚀及其它钢铁材料的腐蚀,此外,桥梁中的砼材料也会与环境的酸性介质发生腐蚀.  相似文献   

20.
为研究不同连接方式装配式混凝土桥墩的抗震性能,进行了2根装配式混凝土桥墩(连接构造分别为钢管剪力键和灌浆套筒)和1根现浇整体式混凝土桥墩的拟静力试验,分析对比试件的滞回曲线、骨架曲线、延性、刚度退化和耗能能力,采用ABAQUS通用程序建立有限元模型,并开展了有限元参数分析. 研究结果表明:3类桥墩试件水平荷载-位移滞回曲线较饱满,具有良好的抗震性能,均为整体压弯破坏,无明显的强度退化,累积耗能能力相近;在不同轴压比、长细比、混凝土强度和钢筋强度条件下,带钢管剪力键的装配式混凝土桥墩的水平峰值荷载和位移延性系数均优于传统灌浆套筒连接的装配式桥墩,提高幅值分别为4%~32%和8%~36%;轴压比、长细比、钢管剪力键嵌入深度和钢管直径是影响钢管剪力键连接的装配式混凝土桥墩抗震性能的重要参数.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号