锁闭检查器接点电气绝缘特性的改进措施
引用本文:范春艳.锁闭检查器接点电气绝缘特性的改进措施[J].铁道通信信号,2012,48(1):29-31.
作者姓名:范春艳
作者单位:西安全路通号器材研究有限公司,西安,710048
摘    要:在现场使用过程中,锁闭检查器(包括VCC和VPM)表示部分存在绝缘电阻低的问题。通过更换接点材料和对原接点材料进行绝缘处理并结合12个周期交变湿热实验数据分析,提出2种提高道岔锁闭器接点系统绝缘性能的方案。

关 键 词:锁闭检查器  酚醛玻璃纤维模塑料  环氧绝缘清漆

Two Ways to Improve the Contact Insulation of Switch Locking Devices
Fan Chunyan.Two Ways to Improve the Contact Insulation of Switch Locking Devices[J].Railway Signalling & Communication,2012,48(1):29-31.
Authors:Fan Chunyan
Institution:Fan Chunyan
Abstract:In the process of field application,poor insulation resistance exists in the indication part of switch locking devices,including VCC and VPM.Through replacing contact materials or conducting insulation processing of materials for the existing contacts,two solutions to improve the insulation of the system were proposed by analyzing the data from a 12 cycle alternating hot and humid experiment.
Keywords:Switch locking device  Phenol glass fiber membrane  Epoxy insulating varnish