首页 | 本学科首页   官方微博 | 高级检索  
     检索      

EFFECTS OF THROMBOLYSIS WITH ULTRASOUND ON THE STRUCTURE OF ERYTHROCYTE AND ITS SAFETY THRESHOLD
作者姓名:严碧歌
作者单位:Applied Acoustics Institute, Shaanxi Normal University, Xi'an 710062, China
基金项目:国家自然科学基金;陕西省自然科学基金
摘    要:The study was to investigate thrombolysis in vitro with ultrasound, and to discuss effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold under different ultrasound intensity and exposure time. The structure of erythrocyte in thrombus was evaluated under light microscope. The relationship between the structure of erythrocyte in thrombus and ultrasound intensity and exposure time was obtained. The results showed that ultrasound eliminated the thrombus. According to the change of the structure of erythrocyte in thrombus and ultrasound intensity and exposure time, the effects of thrombolysis with ultrasound could be divided into three kinds of areas: the A, B, C area. The area A was the safe area, the area B was the relatively safe area, and the area C was the irreversible damage area. The study suggested that ultrasound intensity and exposure time had significant impact on the structure of erythrocyte. Stronger ultrasound intensity or longer exposure time could cause erythrocytes irreversible damage. It could accelerate thrombolysis and shorten the exposure time that the ultrasound intensity was little bit increased. The study of effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold were important for practical applications.

关 键 词:超声  溶解血栓的  红血球结构  安全区域
文章编号:1671-8267(2006)02-0139-03

EFFECTS OF THROMBOLYSIS WITH ULTRASOUND ON THE STRUCTURE OF ERYTHROCYTE AND ITS SAFETY THRESHOLD
Yan Bige.EFFECTS OF THROMBOLYSIS WITH ULTRASOUND ON THE STRUCTURE OF ERYTHROCYTE AND ITS SAFETY THRESHOLD[J].Academic Journal of Xi’an Jiaotong University,2006,18(2):139-141.
Authors:Yan Bige
Abstract:The study was to investigate thrombolysis in vitro with ultrasound, and to discuss effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold under different ultrasound intensity and exposure time. The structure of erythrocyte in thrombus was evaluated under light microscope. The relationship between the structure of erythrocyte in thrombus and ultrasound intensity and exposure time was obtained. The results showed that ultrasound eliminated the thrombus. According to the change of the structure of erythrocyte in thrombus and ultrasound intensity and exposure time, the effects of thrombolysis with ultrasound could be divided into three kinds of areas: the A, B, C area. The area A was the safe area, the area B was the relatively safe area, and the area C was the irreversible damage area. The study suggested that ultrasound intensity and exposure time had significant impact on the structure of erythrocyte. Stronger ultrasound intensity or longer exposure time could cause erythrocytes irreversible damage. It could accelerate thrombolysis and shorten the exposure time that the ultrasound intensity was little bit increased. The study of effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold were important for practical applications.
Keywords:ultrasound  thrombolysis  erythrocyte structure  safe area
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号